AMS Flashcards
Pack 1(2) button out, cosa succede?
Manually closes the respective pack flow control valve.
Recirc button che fa?
IN: automatic operation by AMS, turns on both recirc fan, according to logic.
OUT: recirc fans turned OFF
Se Bleed 1(2) button pushed out, cosa succede a livello di anti ice?
La engine bleed viene chiusa, quindi engine antice sará ancora usabile, mentre wing anti ice viene escluso.
Dump button che fa?
Serve per avere una rapida depressurizzazione.
ECS packs + recirc fans OFF
Outflow valve to maintain a rate of climb 2000 ft/min.
When cabin altitude of 12400ft is reached, the outflow valve is commanded CLOSED.
From this point the cabin altitude rises by natural leak.
Mettendo entrambi i pacchi su OFF, si attiverà la Emergency RAM air.
If the cabin altitude is above 12400 ft when dump button is activated, the cabin altitude may be rising due to normal leak.
Se però la pressurization mode è in manual, la outflow valve non si aprirà automaticamente.
Premuto una seconda volta ritorna tutto a operare normalmente.
Nella synoptic page come differenzi lo stato FAIL da quello UNDETERMINED?
Se UNDETERMINED avrà il contorno amber dashed e basta, se FAILED contorno amber dashed e con sopra una amber cross.
Leggermente variabile in funzione se è bleed, recirc fan ecc.
In quale caso l’emergency RAM air entra in funzione?
Se entrambi i pacchi sono selezionati OFF oppure sono failed OFF e l’altitudine è minore di 25000 ft.
L’apertura è automatica grazie ad una check valve, quando la RAM pressure è maggiore della cabin pressure.