9 Community Relations And Company Level Inspections Flashcards

1
Q

When dealing with irate citizens one of the first skills company officers need is

A

Effective listening

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Resolving all concerns complaints and inquiries is a duty of

A

All members of the organization

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

If conducted properly fire and life safety inspections can serve two purposes

A

Identify and correct potential life and the life safety hazards.
Demonstrate the organizations concerns for citizen safety and well-being

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Fire and life safety inspections have a twofold purpose

A

Insuring fire and life safety code it hereto in public buildings
Provide owner occupant safety education

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Unless an emergency is in progress on the property, responders cannot enter private property without obtaining

A

Permission from the owner or occupant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

For questions regarding potential code and fractions and if significant life safety issues are found during inspections, company officers should refer to

A

Fire prevention officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Fire resistance rating for type IA construction

A

3 hour structural frame and loadbearing walls.
2 hour floors.
1.5 hour roofs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Fire resistance for type IB construction

A

2 hour load walls and structural members
2 hour floors
1 hour roof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Fire resistance for type IIA construction

A

Structural members similar to type I steel concrete of masonry, 1 hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

IIB fire rating differs from IIA by

A

May not have fire rating.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Type iiia fire resistance

A

2 hour exterior walls

1 hour construction inside

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

IIIB construction fire rating

A

2 hr exterior walls

Lacks 1 hr rating inside like iiib

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Type IV fire rating

A

Members of structural frame are at least 1 hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Min column size of type IV

A

8x8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Floor beam minimum size of type IV

A

Sawn or glulam 6x10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Roof beam min size in type IV

A

8x6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Fire rating of type VA

A

1 hr for all structural elements except non bearing interior walls.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Fire rating of type VB

A

Non fire rated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Company officers primary duty is supervising an emergency response unit, the inspection function secondary to

A

Emergency response duties

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

During inspection all emergency responders have a legal and moral duty to act when they confront

A

Hazardous condition toward life safety

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Most fire codes require buildings to be inspected how many times per year

A

At least once

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

After violation has been reported to the occupant and corrective action explained, The officer must also provide

A

Written documentation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

True false badges and official identification are mandatory for all inspection personnel

A

True

24
Q

Occupancy classification

A

Structural classification from model building code to describe intended use of structure

25
Q

There are three content hazard classification

A

Low hazard
ordinary hazard
high hazard

26
Q

During the closing interview the company officer should meet with the owner and discuss

A

If any violations were found, timeframe for them to be addressed, establish a follow-up date and time, develop correction plan

27
Q

Hey hospital nursing home or other medical facility should be involved in an exit drill

A

Only the staff

28
Q

Most common type of fire detection and signaling systems

A
Local auxiliary 
remote station 
proprietary 
central station 
emergency voice communication
29
Q

Primary purpose of a local alarm system

A

Alert building occupants of fire so they will leave building

30
Q

Secondary purpose of local alarm systems

A

Passerby building fire so they report it

31
Q

Local alarm system

A

Alarm sound to notify only on the premises installed

32
Q

Auxiliary alarm systems

A

Municipal alarm box systems. Alarm sounds notifies fire service dispatch

33
Q

Remote station systems

A

So much municipal alarm box but may travel to phone line or radio box

34
Q

A coded remote station system is necessary at occupancies consisting of buildings at

A

Different locations

35
Q

A non coded remote station system

A

Used where the system covers only one building

36
Q

Proprietary alarm system

A

Covers large complexes where alarms are received at a monitoring area.

37
Q

With on-site water supplies company officer should inspect how well it’s maintained but will not determine the systems

A

Adequacy

38
Q

Stationary fire pumps should be test run for how long weekly

A

At least 30 minutes per week

39
Q

Type a box alarm system

A

Fire alarm boxes are transmitted to dispatch center and must be retransmitted to the appropriate company

40
Q

Type B box alarm systems

A

Boxes received are transmitted to all fire stations

41
Q

Three types of dry sprinkler systems

A

Dry pipe system. Pre-action system. Deluge system

42
Q

Pre-action dry sprinkler system

A

Sprinkler head and secondary detection device must operate before extinguishing agent or water is released into the system

43
Q

Dry chemical systems are used in areas were rapid extinguishment is required but what is unlikely

A

Reignition

44
Q

Two main types of dry chemical systems

A

Local application.

Total flooding

45
Q

Local application dry chemical system

A

Applies extinguishing agent to a specific area like a stove

46
Q

Total flooding dry chemical systems are installed in areas such as

A

Paint spray booths where they have a cloud of agent is needed to fill the entire space when discharged

47
Q

What chemical systems are typically installed and what type of setting

A

Commercial range hoods, plenums, ducks, well-suited for cooking oil related applications

48
Q

Halon and halogenated extinguishing agents contain any atoms from one of the following halogen series of chemicals

A

Fluorine
chlorine
bromine
iodine

49
Q

Two halogenated portable fire extinguishers still in use

A

Halon1211.

Halon 1301

50
Q

CO2 systems like try counsel systems are found in what type

A

Local application and total flooding

51
Q

Replacement halons

A

Halotron
Fm 200
Inergen

52
Q

Phone systems are used in locations where the application of water alone may not be

A

May not be effective in extinguishing fire such as aircraft hangers or storage for flammable liquids

53
Q

Three methods to expel fire extinguishing agent

A

Stored pressure. Cartridge operated. Pump operated

54
Q

Fire extinguishers weighing less than 40 pounds should be installed at the height at

A

The top of the extinguisher no more than 5 feet above the floor

55
Q

Extinguishers way more than 40 pounds except wheeled types should be installed so that the top of the extinguisher is no more than

A

3 1/2 feet above the floor