MACH AIRSPEED WARNING TEST
Verify clacker sounds
STALL WARNING TEST
Hold the button until control column shaker activates.
GROUND PROXIMITY SYS TEST switch (800)
- BELOW G/S and GPWS INOP lights illuminate
- TERR FAIL and TERR TEST display on nav displays
- PULL UP & WINDSHEAR alerts illuminate
- Terrain test pattern displays on nav displays
- “Glideslope”, “Pull up” & “Windshear, wind…” sound
- “Terrain, terrain, pull up” sounds & TERRAIN caution on nav displays
- “Obstacle, obstacle, pull up” sounds
- (If installed) “Airspeed low, airspeed…” sounds
Engine/APU Fire Protection System Check TEST switch … Hold in FAULT/INOP (Indication of a good test)
All illuminate:
- MASTER CAUTION lights
- OVHT/DET annunciator
- FAULT light
- APU DETECTOR INOP light
Engine/APU Fire Protection System Check
TEST switch … Hold in FAULT/INOP
(Indication of a bad test)
If the FAULT light fails to illuminate, the fault monitoring system is inoperative.
Engine/APU Fire Protection System Check
TEST switch … Hold in OVHT/FIRE
(First part of the test)
- Bell sounds
- FIRE WARN lights
- MASTER CAUTION lights
- OVHT/DET annunciator
Engine/APU Fire Protection System Check
TEST switch … Hold in OVHT/FIRE
(after pushing the Master FIRE WARN light)
- Both FIRE WARN light & bell cancel
- Red ENG 1, APU & ENG 2 fire warning switches
- ENG 1 & ENG 2 start levers
- Amber ENG 1 OVERHEAT & ENG 2 OVERHEAT
- Red WHEEL WELL
Engine/APU Fire Protection System Check
TEST switch … Hold in OVHT/FIRE
(Indication of a bad test)
If the FAULT light illuminates during the OVHT/FIRE test, there is a fault on the A or B loop on one or both engines. To determine which loop is good, you must perform a follow on procedure.
Cargo Fire Protection System Check
TEST switch … Push
(First part of test)
- Bell sounds
* FIRE WARN lights
Cargo Fire Protection System Check
TEST switch … Push
(after pushing the Master FIRE WARN light)
- Both FIRE WARN light & bell cancel
- Both small round green EXT lights
- Red FWD & AFT lights
- Amber DISCH light
- Amber DETECTOR FAULT light is OFF
Cargo Fire Protection System Check
TEST switch … Push
(Indication of a bad test)
If a red FWD or AFT warning light does not illuminate and the DETECTOR FAULT light illuminates, a detection loop is inoperative.
What are the engine indications after a good start on a standard day at sea level (800/900/9ER)?
- N1: 19.4%
- N2: 58.8%
- EGT: 410 deg C
- Fuel flow: 600 lbs/hr
What are the engine indications after a good start on a standard day at sea level (Max)?
- N1: 20.1%
- N2: 70.3%
- EGT: 610 deg C
- Fuel flow: 600 lbs/hr
When should you accomplish the Engine Start - Aborted Start checklist?
Any of the following:
- N1 or N2 does not increase or increases very slowly after the EGT increases.
- The is no oil pressure indication by the time the engine is stable at idle.
- The EGT does not increase by 15 seconds after the engine start lever is moved to IDLE.
- EGT rapidly approaches or exceeds the start limit.