36 Pneumatic Flashcards
What are the 7 systems the pneumatic system provides high-pressure air for?
Air conditioning Engine starting Wing anti-icing Water pressurisation Hydraulic reservoir pressurisation
+Fuel Tank Inerting System (FTIS) *if installed
+Cargo hold heating *if installed (not at EZY)
What are the 3 sources of high-pressure air?
Engine bleed systems
APU load compressor
HP ground connection
What is a BMC? How many are there? What do they do?
Bleed Monitoring Computers (x2)
They control and monitor each engine bleed air system.
How many engine bleed air systems are installed on the aircraft?
2
What do the engine bleed air system computers do (BMCs)?
Select the compressor stage to use as a source of air, regulate the bleed air temperature and pressure
What happens if one BMC fails?
The other takes over most of the monitoring functions
Where is air normally bled from?
The intermediate pressure stage (IP) of engine’s high-pressure (HP) compressor - to minimise fuel penalty
At low engine speeds, when the temperature and pressure of the IP air is too low, where is bleed air bled from?
HP stage (maintained at 36+/-4psi)
NEO: HP stage (maintained at 65+/-15psi)
What is the precooler and what does it regulate the temperature to?
Air-to-air heat exchanger that uses cooling air bled from the engine fan to regulate the temperature to approx. 200 degC
Above what APU N% speed will the APU bleed air system supply the pneumatic system?
95% (when AVAIL shows on APU SD page)
What is the function of the leak detection system in the pneumatic system?
To detect any overheating near the hot air ducts in the fuselage, pylons, and wings.
How many wing bleed leak detection loops need to detect a leak to activate a wing leak signal?
Two (or one if the other is inoperative)
What 3 things happens automatically if a wing/pylon/APU bleed leak is detected?
Bleed valve on the related side closes
FAULT light on associated pb on AIR COND panel
Crossbleed valve closes (except during engine start)
APU bleed valve closes (if it was open, and the leak concerns the left wing, pylon 1, or the APU)
When does the precooler inlet pressure become amber?
Below 4psi or above 57-60psi (set by BMC)
When does the precooler outlet temperature become amber?
> 290 degC for more than 5 seconds
270 degC for more than 15 seconds
257 degC for more than 55 seconds
or
<150 degC