What is the Upper Explosive Limit (UEL) of Propane?
9.5
What is the best procedure when a propane tank is venting and the escaping product is burning?
Cool the tank at the vapor space
The explosive range of Carbon Monoxide is ____ and _____.
12.8% (LEL); 74% (UEL)
Any structure should be immediately evacuated if the CO level is ____ ppm or above.
35
What is the minimum limit of approach for a power line with 50,000 volts?
10 feet
What is the safest insulator for electricity?
Distance
How far away should you stay from a vehicle that has down wires on it?
30’
On a power pole there are two lines of numbers, what does the top line indicate?
Map Grid
On a power pole there are two lines of numbers, what does the bottom line indicate?
Specific pole number
The ___________ is a wooden bar located at the top of a utility pole. It keeps the power lines separated by a sufficient distance to prevent arching.
Cross Arm
Per APWA, a RED marker/flag indicates which of the following utility:
Electric, cable, conduit and lighting cable
Per APWA, a PURPLE marker/flag indicates which of the following utility:
Reclaimed water, irrigation and slurry lines
What is the flammable range for natural gas?
5% - 15%
What does the acronym BLEVE stand for?
Boiling Liquid Expanding Vapor Explosion
If a break is in a line that is reported to be over __ inches in diameter, the incident should be upgraded to a hazardous materials response because of the increased risk of large amounts of escaping flammable gasses.
2”
The proper sequence for shutting off the utility in either a leak or fire situation is:
At the appliance (if safe), at the meter, at the curb box
To protect the utility company workers, units should position upwind with ______ when necessary:
20lb dry chemical extinguisher and a charged hoseline
For outside gas leaks, the DOT Emergency Response Guide (ERG) suggests an evacuation distance of:
330 feet
Fire department personnel may perform clamping or crimping of a leak when:
Only in extreme cases for lines that are 0.75” or smaller
When should the gas be turned off at the curb box?
In the event that the shut-off on the inside of a residential installation cannot be operated due to fire or accessibility
For outside propane tank fires or tanks that are exposed to fire, the initial attack line should be:
1.75” along with an additional backup 1.75” line
NIOSH has established ___ ppm of Carbon Monoxide as the acceptable level for commercial buildings
35
If the detection/monitoring equipment shows a reading of __ ppm of CO, the occupancy shall be immediately evacuated, and crews should retreat and don their SCBA
35
At an incident where an individual is in a vehicle that has downed wires, personnel should stay how far away from the vehicle until power can be locked out
30 feet