Utilities Manual Flashcards
What is the Upper Explosive Limit (UEL) of Propane?
9.5
What is the best procedure when a propane tank is venting and the escaping product is burning?
Cool the tank at the vapor space
The explosive range of Carbon Monoxide is ____ and _____.
12.8% (LEL); 74% (UEL)
Any structure should be immediately evacuated if the CO level is ____ ppm or above.
35
What is the minimum limit of approach for a power line with 50,000 volts?
10 feet
What is the safest insulator for electricity?
Distance
How far away should you stay from a vehicle that has down wires on it?
30’
On a power pole there are two lines of numbers, what does the top line indicate?
Map Grid
On a power pole there are two lines of numbers, what does the bottom line indicate?
Specific pole number
The ___________ is a wooden bar located at the top of a utility pole. It keeps the power lines separated by a sufficient distance to prevent arching.
Cross Arm
Per APWA, a RED marker/flag indicates which of the following utility:
Electric, cable, conduit and lighting cable
Per APWA, a PURPLE marker/flag indicates which of the following utility:
Reclaimed water, irrigation and slurry lines
What is the flammable range for natural gas?
5% - 15%
What does the acronym BLEVE stand for?
Boiling Liquid Expanding Vapor Explosion
If a break is in a line that is reported to be over __ inches in diameter, the incident should be upgraded to a hazardous materials response because of the increased risk of large amounts of escaping flammable gasses.
2”
The proper sequence for shutting off the utility in either a leak or fire situation is:
At the appliance (if safe), at the meter, at the curb box
To protect the utility company workers, units should position upwind with ______ when necessary:
20lb dry chemical extinguisher and a charged hoseline
For outside gas leaks, the DOT Emergency Response Guide (ERG) suggests an evacuation distance of:
330 feet
Fire department personnel may perform clamping or crimping of a leak when:
Only in extreme cases for lines that are 0.75” or smaller
When should the gas be turned off at the curb box?
In the event that the shut-off on the inside of a residential installation cannot be operated due to fire or accessibility
For outside propane tank fires or tanks that are exposed to fire, the initial attack line should be:
1.75” along with an additional backup 1.75” line
NIOSH has established ___ ppm of Carbon Monoxide as the acceptable level for commercial buildings
35
If the detection/monitoring equipment shows a reading of __ ppm of CO, the occupancy shall be immediately evacuated, and crews should retreat and don their SCBA
35
At an incident where an individual is in a vehicle that has downed wires, personnel should stay how far away from the vehicle until power can be locked out
30 feet
The primary method for ventilation in an inside gas leak is_______?
Natural
The piping vent pipe will be within____ of the vent on an inside wall?
5 feet
What is the initial alarm for an inside gas leak?
2 engine companies, 1 truck or rescue, 1 Battalion Chief