TS 3.1.7 REGULATING CEA INSERTION LIMITS Flashcards
MODES of applicability?
Modes 1 and 2
When is LCO not applicable?
While conducting CEA testing (SR 3.1.5.3) or up to 2 hours following a RPCB
If REG CEA’s are inserted beyond transient insertion limits with COLSS in or out of service, what is required?
Restore REG CEA’s to within limits (2 hours) OR Reduce Thermal Power to < than or equal to COLR limit (2 HR)
If REG CEA’s are in between short term and transient insertion limits for > 4 hours per 24 hours, what is required?
Restrict RTP increases to < 5% per hour (in 15 minutes)
If REG CEA’s are between long term and transient insertion limits for >5 days per 30 EFPD or >14 per 365 EFPD, what is required?
Restore REG CEA’s to within limits in 2 HOURS
When the PDIL alarm circuit is INOPERABLE, what is done?
Verify each CEA is within limits in 1 HR and Once per 4 HR thereafter