Q
Reactivity shall be controlled by what 3 things?
A
a. SDM shall be > COLR value
b. K(N-1) shall be <0.99 when Tc < 500F
c. RX Criticality shall not be achieved with shutdown group CEA movement
2
Q
MODES of applicability?
A
Modes 3, 4 and 5 with RX Trip Breakers CLOSED and CEA drive system capable of CEA withdrawal
3
Q
SDM not in Limits?
A
CONDITION A: Borate in 15 minutes
4
Q
K(N-1) not in Limit OR RX criticality by Shutdown group?
A
Vary CEA’s AND Borate (both in 15 minutes)