TS 3.4.1 RCS Pressure, Temperature, and Flow DNB Limits Flashcards
LCO 3.4.1 RCS DNB Parameters for PZR Pressure, cold leg temperature, and RCS total flow rate shall be within the limits specified below:
a. PZR Pressure ___
b. RCS Cold Leg temperature ___
c. RCS total flow rate ___
a. 2130 psia to 2295 psia
b. …Tc shall be within area of acceptable ops shown in Figure 3.4.1-1
c. > 155.8 E6 lbm/hour
LCO 3.4.1 APPLICABILITY
RCS Total Flow Rate ___
PZR Pressure ___
RCS Tcold ___
Flow = MODE 1
PZR Pressure = MODES 1 and 2
Tcold = MODE 1 (and MODE 2 with Keff >1)
LCO 3.4.1
APPLICABILITY - NOTE ___
NOTE
PZR Pressure limit does NOT apply during:
a. THERMAL POWER ramp >5% RTP/minute
b. THERMAL POWER step >10% RTP
LCO 3.4.1 Bases address requirements for maintaining RCS pressure, temperature, and flow rate within limits assumed in the ___
Safety Analyses
In MODES 1 and 2 for these parameters, the limits must be maintained during steady state ops in order to ensure that DNBR criteria will be met in event of unplanned LOFC or other DNB limited transient. In all other MODES, the power level is low enough so that ___
…DNBR is NOT a concern
LCO 3.4.1 CONDITION
A. RCS flow rate not within limit
A.1 Restore RCS flow rate to within limit (2 hours)
RCS flow rate is not a controllable parameter and is not expected to vary during steady state ops. If the flow rate is not within the LCO limit, then ___
…power must be reduced, as required by Required Action B.1, to restore DNB margin…
LCO 3.4.1 CONDITION
B. Required Action and associated Completion Time of Condition A not met.
B.1 Be in MODE 2 (6 hours)
LCO 3.4.1 CONDITION
C. PZR Pressure or RCS cold leg temperature not within limits.
C.1 Restore parameter(s) within limits (2 hours)
LCO 3.4.1 CONDITION
D. Required Action and associated Completion Time of Condition C not met.
D.1 Be in MODE 3 (6 hours)
LCO 3.4.1 Figure 3.4.1-1
Tcold Minimum ___
Tcold Maximum ___
MIN - (0% to 100% is always 550 F per 3.4.1)
MAX - (at 0% 570F, ramping down to 100% 564F)