Tech Specs Flashcards
3.1.3 CONTROL ROD OPERABILITY
Modes 1 &2 1 W/D ROD STUCK --DISARM IN 2 HRS --CRD EX IN 24 HRS --SDM IN 72 HRS 2+ W/D RODS STUCK --DISARM in 2 HRS & MODE 3 IN 12 1+ CR INOP FOR other REASONS --FULLY INSERT in 3 HRS & DISARM in 4 HRS 2+ INOP CR not in Comp with BPWS --Restore to OPER in 4HRS Or Restore Comp with BPWS in 4 hrs 9+ CR INOP --Mode 3 in 12 HRS
3.4.1 2 Recirc Loops w/match flows or SINGLE w/Limits applied
Modes 1 & 2
NOT MET Satisfy in 24 HRS
Time Limit or NO RECIRC Mode 3 in 12 HRS
3.4.5 RCS LKG Detection
Modes 1,2, & 3 DWFD Mon INOP Restore in 30 days FPM Part/Gas both INOP Grab Samples Once/12 hrs & Restore in 30 Days ALL INOP 3.0.3 Immediately
3.4.7 SDC-Hot Shutdown-2 Loops Operable and 1 in operation if No Recirc
Mode 3 < 138 psig
1+ SDC Loops INOP Restore Immed &
Ver Alt DHR for each INOP in 1 hr
AND Mode 4 in 24 hrs
NO SDC or RECIRC in operation Restore 1 sys Immed &
Verify Alt Circ in 1 hr & Once/12 & Mon Rx Cool temp/press hrly
3.5.1 ECCS and ADS
Modes 1 & 2/3 >150 for HPCI/ADS 1 LOW PRESS -- 7 days HPCI -- RCIC 1 HR & 14 days HPC1/1 LO PRESS --restore 72 hours 2+ ADS -- 12 / 36 2+ LO PRESS -- 3.0.3 HPCI/2 ADS -- 3.0.3
3.6.1.3 Each PCIV except rx/torus
Vac Brkr Operable
Modes1,2 &3 when inst req’d to be operable 1+ Pen w/1 PCIV INOP --ISOL 4 hr/8 hr MSL/ Ver 31 days 1+ Pen w/2 INOP --ISOL in 1 hour 1+ Pen w 1 INOP if ONLY 1 --ISOL in 4 hr (EFCV 12 hr) Ver 31d 1+ Pen w/lkg unaccept --Restore 4 hr Otherwise --3 in 12/4 in 36
3.6.1.3 Each PCIV except rx/torus
Vac Brkr Operable
Mode 4 & 5
Req’d PCIV INOP
–Suspend OPDRV’S OR
Return SDC PCIV’s to Operable
3.7.2 PSW
1,2,3 1 PUMP or 1 TB ISOL -- 30 days 1 PUMP IN EACH LOOP -- 7 days 1 TB ISOL in EACH LOOP -- 72 hrs 1 SUBSYSTEM INOP -- 72 hrs BOTH SUBSYS OR UHS -- 3 in 12 / 4 in 36
3.8.1 AC SOURCES OP
Modes 1,2, 3
1 OFFSITE CKT Brkr Align 1/8 HRS and
Dec Feat w/no offsite INOP in 24
And Restore 72 hrs/17 days
1 same unit or swing DG Brkr Align 1/8 HRS and
Dec Supp Feat INOP if Red in 4
Surv or Comm Cause in 24 hrs
Restore 72 hrs/14 days/17 days
1 opposite Unit DG Brkr Align 1/8 HRS and
Dec Feat w/no offsite INOP in 4
Surv or Comm Cause in 24 hrs
Restore 7days/14 days
2+ Offsite CKT Dec Feat w/no offsite INOP in 12
AND Restore All but 1 /24 hrs
1 offsite ckt and 1 Req’d DG Restore Either in 12 hours
2+ SameU or Swing DG Restore All but 1 in 2 hrs
No DG capable U2 LPCI lc Restore 1 in 2 hrs
1+ Offsite and 2+ DG or
2+ Offsite and 1 DG 3.0.3 Immed
3.8.7 Dist Sys OPER
Modes 1, 2,3 1+ Opp Unit AC or DC Restore 7 days 1+ Same U/Swing DG DC Restore 12 hrs/16 hrs 3.8.7.a 1+ Listed Bus 8 hours 1 Sta Svc DC 2 hours 2+ Subsys that cause LOF 3.0.3 Immed
3.9.1 R/F Interlocks
Modes: Invessel Fuel Moves
1+ Intlk INOP Suspend Immed OR
Insert ROD BLOCK and All Rods IN
3.9.2 R/F 1 Rod Out Interlock
Modes: 5/Mode Sw in RF/any Rod out
R/F 1 rod out intlk INOP Suspend CR w/d and ALL Insertable Rods IN
3.9.3 CR Position
Mdoes: Loading Fuel into vessel
1+ CR Withdrawn Suspend Fuel Load Immed
3.9.4 C/R Full IN POS
Mode 5 1+ W/D CR INOP --Suspend Invessel Fuel --Suspend CR W/D --Insert Rods in cells w/fuel OR Insert CR w/INOP FI ind AND Disarm Immed
3.9.5 Each WD CR Operable
Mode 5
1+ WD CR Inop INSERT Immediately