Immediate Operator Actions Flashcards
34AB-B31-001-2 Reactor Recirc Pump Trip, or Recirc Loops Flow Mismatch
Immediate Operator Actions
Immediate Operator Action
a. Loss of both Reactor recirc pumps - Enter 34AAB-C71-001
and Scram
34AB-C51-001-2 Entry Into the Region of Potential Instabilities (RPI) OR Reactor Operations with Inoperable
OPRM System
Immediate Operator Actions
At any point on any power vs flow map the following conditions exist, enter 34AB-C71-001-2 AND SCRAM:
- Peak to Peak bandwith oscillations any APRM exceeds 10%
AND
-The cause is unknown
OR
- the cause is believed to be the result of core thermal hydraulic instabilities
34AB-C71-001-2 SCRAM Procedure
Immediate Operator Actions
Immediate Operator Action - Perform RC-1, RC-2, and RC-3
34AB-E10-001-2 Inadvertent Initiation
of ECCS/RCIC
Immediate Operator Actions
Confirm validity of ECCS/RCIC initiation signal by observing multiple
independent parameters.
IF the ECCS initiation signal is not valid and injection is imminent,
THEN immediately shutdown affected systems to prevent injection.
IF ADS timers inadvertently initiated,
Inhibit ADS using 2B21-S7A AND 2B21-S7B, ADS Auto Logic Inhibit
Switches, on 2H11-P602.
IF the RCIC initiation signal is not valid,
THEN depress the RCIC Turbine Trip push-button to shutdown the
system.
IF RCIC Turbine Trip push button fails to trip RCIC, trip RCIC by closing
2E51-F524, Trip and Throttle Valve.
34AB-N21-001-2 Loss of Feedwater Heating
Immediate Operator Actions
Immediate Operator Action:
Using Fast Lower, Maintain reactor power at least 1% below steady
state level prior to feedwater temperature reduction using Recirc
(exceed 10 Mwe/min)
34AB-R22-002-2 Loss of 4160V Emergency Bus
Immediate Operator Actions
Immediate Operator Action:
Ensure Diesel Generator for affected bus has auto-started.
31RS-OPS-001-2 Control Room Evac
Immediate Operator Actions
Immediate Operator Action:
Prior to Exiting the Control Room
Enter 34AB-C71-001-2, AND SCRAM the Reactor.
If Rx is S/D, Shutdown the Mn Turb and perform TC-1
Place Lvl Cntrl in SINGLE ELEMENT and perform RC-2
Additional: Announce situation, Direct Ops and HP to RSDP, Grab radios
and phones, send someone to TSC for SPDS