TB 112 Foam Tender Flashcards

1
Q

The Foam Tender is built on a Freightliner FL112 chassis with a _____.

A

Cummins model ISM 450 “Celect-Plus” engine.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The transmission is an _____, five speed fully electronic automatic transmission.

A

Allison World HD 4060P

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A _____ Class “A” foam concentrate tank.

A

200-gallon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

A _____ Class “B” foam concentrate tank.

A

1000-gallon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

____ foam concentrate pumps.

A

Two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A _____ air compressor used for either the compressed air foam system or pneumatic tools such as those used by USAR apparatus.

A

400 cubic foot per minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

___ large top mounted monitors.

A

Two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Large capacity ____ and _____.

A

water inlets / water discharges

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Two _____ dry chemical “Purple-K” systems.

A

350-pound (total of 700 pounds)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

____ passenger seating.

A

Two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Flow large volumes of water (in excess of ____).

A

4000 GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Flow large volumes ____ and _____.

A

Class “A” foam / Class “B” foam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Add _____ to either the Class “A” or the Class “B” foam systems

A

compressed air (CAFS)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Discharge _____ from large capacity onboard tanks, alone or in conjunction with Class “B” foam

A

dry chemical (i.e. “Purple K”)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Provide____ with onboard booms.

A

hydrocarbon spill containment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Re-supply another Foam Tender or other apparatus with _____ concentrates.

A

Class “A” or Class “B” foam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

The L.A.F.D. Foam Tender does not have a _____.

A

fire pump or a water tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

The Foam Tender relies on______ for its water supply.

A

independent pumping apparatus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

When practical, the Foam Tender should be supplied by ____ apparatus.

A

up to three pumping

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

When supplied by an adequate water service, the Foam Tender will flow _____ from various monitors and discharge outlets.

A

4,000 gallons per minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

A top mounted front monitor flowing up to ____ gallons per minute.

A

1,500

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

A top mounted rear monitor flowing up to _____ gallons per minute.

A

2,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

A passenger side discharge flowing up to ____ gallons per minute.

A

800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

A rear discharge flowing up to ____ gallons per minute.

A

2,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

A driver side discharge flowing up to ____ gallons per minute.

A

800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

A Hale adjustable relief valve allows the operator to control discharge pressure between _____.

A

30 to 250 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Incoming water pressure is controlled by a pre-set relief valve that automatically discharges excess water pressure (_____) to the ground.

A

over 250 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

Class A Foam system : The system automatically balances and proportions the foam solution ranging from ____.

A

0.3% to 1.0%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

Class A Foam : ____ gallons per minute at 1.0%.

A

2,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

Class A Foam : ____ gallons per minute at 0.5%.

A

4,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

The “A” system concentrate pump is powered by a hydraulic drive system that is driven by a transmission power takeoff (PTO). The Class “A” foam system is capable of pumping ____ of concentrate per minute.

A

24 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

A 200-gallon Class “A” concentrate tank. The tank can be filled from an external source by using the ___________, or by manually filling from the top.

A

concentrate pump to educt concentrate into the tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

Class A Foam System : ____ Class “A” foam metering valves, adjustable from 0.3% to 1.0%.

A

Four

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

Class A Foam System : One 1-1/2” Class “A” concentrate inlet and one 1-1/2” Class “A” concentrate ____ used to transfer Class “A” concentrate.

A

outlet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

A ____ hose reel used to transfer Class “A” concentrate to other apparatus.

A

110-foot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

It should be noted that Class “A” foam solution can be discharged from both _____ and all ____ on this apparatus.

A

top mounted monitors / discharges

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

Class B Foam System : The system automatically balances and proportions the foam solution ranging from ____ despite variations in water pressure or flow.

A

1.0% to 10.0%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

Class B Foam System : The system accurately meters concentrate when water, flowing from _____, passes through the system.

A

70 gpm to 4,000 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

Class B Foam System : The system accurately proportions concentrate into the water stream at operating pressures of _____.

A

70 to 250 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

Class B Foam System : The concentrate pump is powered by a hydraulic drive system that is driven by a transmission power takeoff (PTO). It should be noted that the hydraulic system can only power _____ at a time.

A

one concentrate pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

Class B Foam System : The Class “B” concentrate pump can pump ____ per minute.

A

350 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

Class B Foam System : ___ Class “B” foam adjustable metering valves, adjustable from 1.0% to 10.0%

A

Four

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

The Department provides _____. AR-AFFF foams are based on aqueous film forming foam (AFFF) chemistry to which a polymer has been added.

A

Class “B” 3% AR-AFFF foam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
44
Q

AR-AFFF foams are the most versatile _____ in that they are effective on fires involving water-soluble polar solvents (i.e. methanol, alcohol, acetone, etc.) as well as ______ (i.e. gasoline, fuel oils, etc.).

A

Class “B” foam agents / water-insoluble hydrocarbon fires

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
45
Q

AR-AFFF Class “B” foam has the ability to “selfheal” which means that when disturbed or disrupted it will _____ over the fuel surfaces.

A

redistribute itself

46
Q

This provides ____ and an effective vapor suppression seal. The Foam Tender can pump other foam products; however, different foam concentrates should ____ be mixed in the foam tank.

A

re-ignition protection / never

47
Q

The Foam Tender is equipped with a ____ air compressor to supply air for compressed air foam (CAFS).

A

rotary screw type

48
Q

The air compressor is powered by the vehicle’s engine through a ____ transmission. The compressor delivers air at ______ (CFM) at _____ (PSI).

A

split shaft pump / 400 cubic feet per minute / 150 pounds per square inch

49
Q

Most Class “A” and “B” foams are considered “____.” Aspirating the air into the foam at the nozzle forms a low-energy foam.

A

low-energy

50
Q

The reason these foams are called “low-energy” is that, after the air is aspirated into the stream, the resulting fire stream has relatively ____, or “energy.”

A

low velocity

51
Q

Compressed air foams are considered “_____” because they convert the energy from compressed air into increased _____ and improved _____.

A

high-energy / foam stream reach / foam production

52
Q

Compressed air foam (CAFS) : ____ (how fast a given amount of water drops out of the bubble structure and becomes free).

A

Longer drain time

53
Q

Compressed air foam (CAFS) : _____ that reduces water runoff and water damage. This keeps the incident impact area as small as possible.

A

Drier foam

54
Q

Compressed air foam (CAFS) : Hose lines with compressed air foam are _____ than those filled with water or foam solution.

A

significantly lighter

55
Q

Compressed air foam (CAFS) : No ____ in hose lines.

A

friction loss

56
Q

Compressed air foam (CAFS) : The elimination of ____ when the discharge is opened or shut down rapidly.

A

water hammer

57
Q

The Foam Tender is equipped with two interconnected ______.

A

350-pound dry chemical systems (for a total of 700 pounds total).

58
Q

Ansul Purple K Dry Chemical System : Each system is located in the ____ on each side of the apparatus.

A

forward compartment

59
Q

Ansul Purple K Dry Chemical System : Located next to each 350-pound dry chemical container is a _____ used to pressurize the dry chemical system.

A

220-cubic foot Nitrogen cylinder

60
Q

Ansul Purple K Dry Chemical System : The two dry chemical systems can be used ______.

A

simultaneously or independently.

61
Q

The dry chemical system can be discharged through the front monitor’s _____ or through either of the ____ nozzles, preconnected to the 150-foot chemical hose reels provided on either side of the apparatus.

A

Hydro- Chem nozzle / “Williams” hand line /

62
Q

“Purple K” dry chemical agent contains specially processed ____ which is particularly effective on Class “B” flammable liquids and lower pressure flammable gasses.

A

potassium bicarbonate

63
Q

“Purple K” when used alone is _____.

A

electrically non-conductive

64
Q

It is generally accepted that when the powder is introduced directly into the fire area, it extinguishes the fire by interfering with the ____.

A

chemical chain reaction

65
Q

The Hydro-Chem nozzle and the Williams handgun nozzle, when discharging “Purple K” and foam simultaneously, combines the ____ of dry chemical and the ____ capability of foam.

A

rapid fire extinguishing capabilities / sealing and securing

66
Q

The dry chemical is carried within the _______, to greater distances, thereby extending the safe working distance for the firefighters.

A

nozzle stream, foam solution or compressed air foam

67
Q

The Foam Tender’s front monitor is equipped with a Williams “Hydro-Chem Ranger” nozzle that ______ into its stream.

A

incorporates dry chemical, foam solution, and/or CAFS

68
Q

The benefit that the “Hydro- Chem” nozzle provides is “Purple K” dry chemical injection in the foam/water stream (____), thus carrying the “Purple K” greater distances.

A

20 lb./sec.

69
Q

The “Purple K” dry chemical is introduced into the nozzle from a ____ on the side of the nozzle body. Attached to this chemical inlet is a _____ that is plumbed directly from the dry chemical systems.

A

1-1/2” chemical inlet / flexible plastic hose

70
Q

The Foam Tender’s electronically controlled rear monitor can be equipped with one of the following tips that are provided with the apparatus:

A

An Akron #3489 2-1/2” smooth bore tip / An Akron # 5078 Akromatic 2000 electronic spray tip / Williams “Hydro-Foam” spray tip

71
Q

An Akron #3489 2-1/2” smooth bore tip: This tip provides an effective straight stream pattern up to ___ while flowing ______ . Best for compressed air foam applications.

A

250’ / 2,000 gallons per minute

72
Q

An Akron # 5078 Akromatic 2000 electronic spray tip: This tip provides an effective stream, while flowing foam solution ____ CAFS. The discharge pattern is electronically adjustable from full fog to straight stream. This tip can be controlled at the operator panel or via a ____ tethered handheld hard-wired remote control.

A

with or without / 20-foot

73
Q

Williams “Hydro-Foam” spray tip: This tip provides an effective stream, while accurately metering foam solution _____. The discharge pattern is adjustable from full fog to straight stream. This tip is self-educting and should be used only if there is a foam system ____. Since the monitor is electronic, the operator can control the selected tip elevation, rotation and spray pattern (only the pattern on the Akron spray tip can be controlled from a remote location).

A

with or without CAFS / malfunction

74
Q

The Williams “Handgun” nozzle combines the effective range of a standard nozzle with the capability of ____into its stream.

A

incorporating dry chemical, foam solution, and/or CAFS

75
Q

The Williams “Handgun” nozzle : The nozzle body has two control levers, one to control the ____ and the other to control the _____.

A

water/foam solution / “Purple K” dry powder

76
Q

The Foam Tender is equipped with two ____, each 150 feet long. Each reel is located in the forward compartment on both sides of the apparatus; just above the Ansul “Purple K” dry chemical system. A “Handgun” nozzle is pre-attached to each of these hose reels. A ____ handline must also be attached to the “Handgun” in order to supply foam solution to the nozzle.

A

1” chemical hose reels / 1-1/2” or 1-3/4”

77
Q

Each Foam Tender is equipped with a compliment of ____ to be used in controlling large hydrocarbon spills. Also provided is a spill and leak containment kit for _____.

A

containment and absorption Booms / smaller spills

78
Q

The small kit contains ___ pads, ___ 48” socks, and ___ clean-up bags.

A

50 / five / four

79
Q

For larger spills, there are ___ ____ polypropylene oil-only Booms designed to be linked together for use on water or land.

A

sixteen 4”x10’

80
Q

These booms maintain their buoyancy even when saturated and can absorb up to ___ their own weight of the product. Booms do not ____, only ____. These containment tools will only be effective in controlling spills of water-insoluble hydrocarbon (i.e. gasoline, fuel oils, etc.).

A

25 times / absorb water / hydrocarbon liquids

81
Q

The Foam Tender hose compliment includes ____ hose located in the transverse hose bed.

A

400 feet of 1-1/2”

82
Q

Engineers should supply the Foam Tender with a minimum of ____. The required flow pressure is ___, to the inlets of the Foam Tender.

A

two 4” supply lines / 100 PSI, in volume

83
Q

If a Foam Tender is needed, request at least ___ of them.

A

two

84
Q

Emergency Consideration: Spot apparatus____ if possible (this is important when using CAFS).

A

upwind and uphill

85
Q

Emergency Consideration: The Foam Tender’s monitors have an effective reach of _____ without wind influence

A

270 feet (with CAFS)

86
Q

The Foam Tender is a multi-use apparatus not only because of its foam flowing capabilities, but also because of its ____, _______, and ______.

A

large air compressor / 700 pounds of “Purple K” dry chemical / vlarge water volume potential.

87
Q

USAR incidents – The 150-PSI 400-CFM air compressor can be used for _____.

A

air tools (i.e. jackhammers, concrete saw, air knife, etc.).

88
Q

Baled goods and “mulch fire” incidents – Class “A” Foam has excellent surfactant capabilities (it speeds up the time it takes the water to penetrate the fuel). The Foam Tender carries 200 gallons of Class “A” Foam and at ____, the lowest setting on the Class “A” foam metering valves; it can produce _____ of solution.

A

0.3% / 60,000 gallons

89
Q

Brush fires – The Foam Tender can be used to_____ to other apparatus, pre-treat exposures with CAFS, and/or assist with mop-up.

A

re-supply Class “A” concentrate

90
Q

Structure fires – The Foam Tender can be used as a large water monitor. It can be spotted near the structure and have both monitors put into operation. The horizontal reach of these monitors is in excess of _____. Together they can discharge _____ per minute of water or foam. The Foam Tender’s master stream output is far more than _____ with their wagon batteries flowing.

A

250 feet / 3,500 gallons / three Triples

91
Q

Structure fires (overhaul) – Class “A” foam can be used to reduce the amount of time it takes for overhaul. It can be discharged through the ____ on the Foam Tender or supplied through the discharge gates to handlines, ladderpipes and portable monitors.

A

two monitors

92
Q

Fuel spill – _____ dry chemical can be used on fuel spills.

A

Class “B” foam and “Purple K”

93
Q

The Class “B” foam can be used to provide a ______. The “Purple K” can be used to _______. With the introduction of CAFS into the foam stream, the Class “B” foam is particularly effective, providing a foam blanket without excessive run-off.

A

blanket of foam over the spilled fuel / protect the members working in the involved area

94
Q

Tanker fire – _____ dry chemical can be used in conjunction on tanker rollovers or tanker fires.

A

Class “B” foam and “Purple K”

95
Q

If members need to enter the area to affect a rescue, “Purple K” can be used for protection of members if ____ occurs.

A

a flash of the fuel

96
Q

Hazardous materials incidents – The Foam Tender has ____ capabilities. The _____ can be used at the incident to contain the spilled product.

A

limited spill containment / containment and absorption booms

97
Q

The Foam Tender has a high center of gravity. Use extra caution when _____.

A

turning corners

98
Q

Front Monitor (Hydro Chem Spray Tip) : GPM / PSI / MISC

A

250-1500 GPM / 100 PSI / Dry Chem Discharge 20 lb/sec

99
Q

Rear Monitor (Hydro-Foam Spray Tip) : GPM / PSI / MISC

A

250-1500 GPM / 100 PSI / Used for system malfunction only

100
Q

Rear Monitor (Akromatic 2000 Spray Tip) : GPM / PSI / MISC

A

500-2000 GPM / 80 PSI / Electronically Controlled Spray Pattern

101
Q
Rear Monitor (Akron Smooth Bore Tip) : GPM / PSI 
2000 GPM
A

116 PSI

102
Q
Rear Monitor (Akron Smooth Bore Tip) : GPM / PSI 
1900 GPM
A

104 PSI

103
Q
Rear Monitor (Akron Smooth Bore Tip) : GPM / PSI 
1800 GPM
A

94 PSI

104
Q
Rear Monitor (Akron Smooth Bore Tip) : GPM / PSI 
1750 GPM
A

89 PSI

105
Q
Rear Monitor (Akron Smooth Bore Tip) : GPM / PSI 
1500 GPM
A

66 PSI

106
Q
Rear Monitor (Akron Smooth Bore Tip) : GPM / PSI 
1250 GPM
A

46 PSI

107
Q

Dry Chemical Hose Reels (Handgun spray nozzle) : GPM / PSI / MISC

A

95 GPM / 100 PSI / Dry Chem Discharge 7lb/ sec

108
Q

Passenger Side Discharge

A

100-800 GPM

109
Q

Rear Discharge

A

500-2000 GPM

110
Q

Driver Side Discharge

A

70-800 GPM