Study Guide-Emergency Electrical Power Panel Flashcards
What powers the EMERGENCY GENERATOR?
Blue hydraulic system pressure generated by the RAT (Ram Air Turbine).
When does the RAT automatically deploy?
Inflight with a loss of power to AC bus 1 and 2.
What is the source of power during RAT deployment and approximately how long does it take?
The aircraft batteries are the sole source of electrical power for the AC and DC Essential Buses until the EMER GEN is online, which takes between 5-10 seconds.
What does the red FAULT light on the RAT & EMER GEN pb indicate?
The EMER GEN is not supplying power to AC and DC Essential Buses.
What does the SMOKE light in the GEN 1 LINE pb indicate?
Smoke detected in the avionics ventilation ducting.
Will there be any other indications of avionics smoke on the overhead panel, other than the SMOKE light on the EMER ELEC PWR panel?
FAULT lights in the EXTRACT and BLOWER pbs on the VENTILATION panel.
1-What happens when you push the GEN 1 LINE pb to OFF?
2-And when is this procedure used?
1-Generator 1 is isolated from the electrical system network and is only providing power to one fuel pump in each wing fuel tank.
2-Smoke procedures
Is there a way to manually deploy the RAT?
Yes the guarded MAN ON pb.
Will the RAT deploy on the ground if the MAN ON pb is pressed?
YES
Do pilots ever use the EMER GEN TEST pb?
No- MX function only.