Septic Quiz Flashcards
1) Disposal fields shall not be installed under a roadway or ______
drive way
2) what is the purpose of the outlet screen of a septic chamber?
- protection
- To maintain seperation
- Suspended solids stay back
3) Gravity system
Open bottom sand filter
The open bottom filter shall not be located whitin:
____m (__’) of a protery line, measure from the foot of the berm
1.5m (5’)
3) Gravity system
Open bottom sand filter
The open bottom filter shall not be located within:
___m (__’) of a water source
15m (50’)
3) Gravity system
Open bottom sand filter
The open bottom filter shall not be located within:
__m (__’) of a watercourse
15m (50’)
3) Gravity system
Open bottom sand filter
The open bottom filter shall not be located within:
__m (__’) of a basement or cellar
9m (30’)
3) Gravity system
Open bottom sand filter
The open bottom filter shall not be located whitin:
__m (___’) of a building without a basement
3m (10’)
1) Disposal fields shall not be installed under a ______ area
paved
1) Disposal fields shall not be installed under any _________
structure
1) Disposal fields shall not be installed under a _________ garden
vegetable
List the minimum clearance requirements for a packaged sewage treatment plant from:
a property line _____
1m (3.25’)
List the minimum clearance requirements for a packaged sewage treatment plant from:
a watercourse _____
15m (50’)
List the minimum clearance requirements for a packaged sewage treatment plant from:
a water source _____
9m (30’)
List the minimum clearance requirements for a packaged sewage treatment plant from:
a building ____
1m (3.25’)
A good installation practice is to install laterals at no greater length than ___m (___’)
30m (100’)