GA IP Flashcards

1
Q

What tool is used to tighten a supply tube on a water tank supply?

A

an adjustable wrench

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What material screws are used on a toilet flange?

A

Brass or corrosion resistant screws

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

If a toilet flange is deeper than the floor what will be used?

A

Max wax (not extension)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Manhole diameter of bottom

A

1M

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Softener - stop used on upstream or downstream?

A

upstream

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Lower boom hand signal

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
A

Crane downward load moment signal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Min air gap?

A

1” or 2x pipe diameter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

min air break?

A

1” or 1x pipe diameter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Manhole cleanout size?

A

8”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

6 urinals, their side distance is 1m, what is the c-c measurement?

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Glycol add on 2 questions

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Max temperature for drain pipe?

A

75 degrees C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Water check valve

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Pipe is 100m on hot side, what is needed?

A

Re-circ

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When using an MJ wye, you need to subtract ___”-___” than actual pipe length

A

1/4”-1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

T or F

you need two vents on an oil interceptor, one on the inlet and one on the outlet

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Min size for oil interceptor vent?

A

1-1/4”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

2” inlet drain to pump, what is the vent size?

A

2” min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

oil interceptor vents min distance between outside _____mm

A

300mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Input tool for air what items are required:-

a) F – Filter ( to filter particles )
b) R – Regulator ( to regulate the pressure )
c) L – Lubricant

A

F,L & R all required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

21) Paint tool/gun/spout for what items required for air used to working this tool:-
a) F – Filter ( to filter particles )
b) R – Regulator ( to regulate the pressure )

A

F and R

c) Important: Lubricant not used on paint spray gun. B.coz oil will goes with paint and destroy the job

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

22) To stop the water for urinal/Water Closet flush valve which tool used:-

A

Flat screw Driver

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Trap arm length maximum for 3” size pipe

A

12’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Single rodding 3” pipe distance =\_\_ m
15m
26
BTU given, how many ton ac need:- a) 12000 BTU = 1 ton b) 18000 BTU = 1.5 ton c) 24000 BTU = 2 ton
27
Commercial hot water tank what temp required?
180 f or 82.2 C
28
14” cast iron pipe, what is OD size ?
14” O.D size
29
Acetylene cylinder how we store long time ?
Ans: - Vertical and fastned.
30
Potable water what we can use? a) Dcap b) Dcva c) Rpba
31
Which solder we can use for drinking?
Ans: - Lead free
32
Which solder we can use ? a) 95/5 b) acidic
Ans: - 95/5
33
What is 95/5 Lead Free Plumbing Wire Solder ?
:- Alloy of 95% - Tin and 5 % ---- Antimony Melting Temperature: - 450 – 464 ℉
34
What is Aquasol Lead Free Plumbing Wire Solder ? Tin - 95.75 , Silver - .25 % Copper – 3 % , Antimony - 1% Melting Temperature:- 416 – 454 ℉
Ans:- All of below:- Tin - 95.75 , Silver - .25 % Copper – 3 % , Antimony - 1% Melting Temperature:- 416 – 454 ℉
35
39) Where is Venturi on Pump?
Ans:- on Suction line of pump or up stream side of pump.
36
What we use underground on copper joint? a) Solder b) brazing c) Flaring
b) brazing
37
how for is toilet flange from Finish wall? a) 11 " b) 12 " c) 13 "
b) 12 "
38
What material screws used to toilet flange :
Ans: - corrosion resistance ( exp. Brass )
39
When 5 Psig test done ?
Ans :- Cross- Connection test
40
45 X 60 roof drain area given, how many drains need ?
Ans:- 4 drains
41
What is the not function of the Pipe Dope? a) Lubricating b) union c) Di-electric
Ans:- C) Di-electric
42
What we have do / maintain on solar System ?
Ans: - Visualise glycol check in system, check with strip, glycol add
43
When pouring the concreate on oxy pipe installed , what we we do ? a) air filled b) Air filling after few time c) Sleeved d) Use something under the concrete
44
Wall hung toilet how we forward little bit to front?
Ans:- Nut adjustment
45
Harness rope not good, what we have to do?
Ans:- replace with new one
46
) Boiler union leak, what we can do? a) Silicone b) Teflon c) tight the union
Ans:- c) Tight the union
47
Which backflow device we used on irrigation?
Ans: - DCVA
48
Which backflow device we used on Chemical/ Toxic/ Hospital/ health safety/ food places?
Ans: - RPBA
49
RPBA maximum height?
Ans: - 1’
50
RPBA maximum height?
Ans:- 5’
51
) If we flushing a new piping with chlorine water, what we have to do?
Ans:- keep Flushing
52
What is the ph-8 level
Ans:- Mild alkine
53
What is Ph-12 Level means?
Ans:- strongly Alkline
54
1/8 fitting angle
Ans: 360/8 = 45 degree
55
copper bend process ?
Ans:- Anneal, slow cool down, bend
56
what hammering in laundry, whats reason?
Ans:- Watter hammering.
57
Bottom floor have 18,000 BTU and top have 12,000, find AC size?
Ans:- Total Btu = 18,000 + 12,000 = 30,000 AC Size = 30,000/12,000 = 2.5 ton
58
What need to instal on air tool before supply to tool? F – Filter ( to filter particles ) R – Regulator ( to regulate the pressure ) L – Lubricant
Ans:- FRL need to install
59
What we have to do if siphonic level is less in the tank?
Ans:- Increase the level
60
What type of system used in reverse Osmosis system.
Ans:- Plastic
61
When Energised equipment used, what need to remember?
Ans: Check its safe
62
20’ ladder, distance from wall?
Ans:- 5’
63
Copper and cast-iron drainage connected, what used? a) Dielectric b) Mech coupling c) Transition coupling
Ans: - Mech Coupling
64
1-1/2 abs pipe how cut?
Ans:- hacksaw or Pipe Cutter
65
1-1/2 Copper DWV pipe how we cut?
Ans: - Pipe Cutter
66
Sink drainage pipe, what is the max temp required?
Ans:- 75 degree Celsius
67
What is the developed length of a 3-compartment sink
Ans: - 1200 mm
68
What is the developed length of a 2-compartment sink?
Ans: - 1200 mm
69
What is the floor drain length, if not vented?
Ans: - 450 mm ( and also if the size of trap not less than 3”, fall on drain not exceed its size)
70
What is the minimum floor drain Size, if not vented?
Ans: - 3”
71
What is the minimum floor drain Size, if vented?
Ans: - 2”
72
What would be required to braze a 2” brass MIP onto a copper tube?
Ans:- High temp flux.
73
Where trap primer install on faucet?
Ans:- Often used faucet
74
To stop the water for urinal/Water Closet flush valve which tool used:-
Ans: - Flat screw Driver
75
What is trench drain ratio?
Ans: 3:4
76
1” pipe how many thread used?
Ans: - 11.5 threads
77
300 EDR equal to how many MBTU ? ( 1EDR = 240 BTU. )
Ans:- 1 EDR = 240 BTU 300 EDR = 300 x 240 = 72000 BTU Now, 1000 BTU = 1 MBTU 1 BTU = 1/1000 MBTU 72,000 BTU = 72,000/ 1000 **= 72 MBTU**
78
88) Acetylene Cylinder how store long term?
Ans: - Fastened and Vertically store.
79
14” cast iron pipe, how much O.D.?
Ans:- 14” O.D
80
Compressor Lock-out procedure steps? Ans: - ?????
81
Fire hydrant Siamese connection size?
Ans: - 65 mm or 2-1/2” Female connection.
82
Why we use Siamese Y connection? .
Ans:- To prevent freezing
83
How long cast iron pipe need to cut, to install wye?
Ans:- ¼” to ½” bigger size
84
Water colour red in toilet tank, what’s the reason?
Ans:- more Iron in water OR ( only 1 came in exam )
85
If water colour black in toilet tank, what’s the reason?
Ans: - Magnesium more in water
86
How many hangers are required on 4” cast iron pipe, if used on 3M and every hub/spigot joint? ' a) 14 b) 15 c) 16 d) 17
87
What is the procedure to assemble compression joint on copper tubing?
Ans : Cut, ream, slide nut and ferrule(also called ring or sleeve) over tubing, push tubing completely into socket then tighten nut 2.
88
What is the procedure to assemble flaring joint on copper tubing?
Ans: - Cut the pipe , Ream the pipe, Put the nut on pipe, Flare the pipe
89
When installing ABS pipes and fitting at -15°C (5°F) bracket, what is done to ensure adhesion? a) Dilute the glue b) Warm up the glue c) Apply more glue d) Apply more pressure
b) Warm up the glue
90
What is the procedure to assemble a hub and spigot gasket joint on plastic pipe?
Ans : Cut Ends of Pipe Square, clean pipe and fitting, Lubricate Gasket and Spigot, then Push spigot into Hub at determined depth
91
If on boiler rating written 30 PSI and 140,000 BTU which T & P valve we need?
Ans: - T & P valve with 30 PSI and 150,000 BTU rating ( means more rating than 140,000 BTU )
92
) If a drain required 900 Square meter, how many drains are required if we have 60 X 45 metre area
Ans: - Area = 60 x 45 = 2700 square meter Drains Required = 2700/ 900 = 3 drains Or We have length = 60 and Width = 45 Drains required for length side = 60/30 = 2 Drains required for Width side = 45/30 = 1.5 means 2 Total drains required = Length wise drains X Width wise drains = 2 x 2 = 4 drains **Note:- Please check, which answer match with given answers**
93
103) What would be installed in the water piping to and a from hydronic unit? a) 1 Isolation valve, 2 Unions, 1 Vent, 1 drain b) 2 Isolation valve, 2 Unions, 1 Vent, 1 drain c) 2 Isolation valve, 2 Unions, 1 Vent d) 1 Isolation valve, 2 Unions, 1 drain
Ans : - b) 2 Isolation valve, 2 Unions, 1 Vent, 1 drain
94
104) What Steps are followed to join Bell & Spigot pipe in draining system?
Ans: - Cut pipe, ream outside pipe and inside spigot, clean, lubricate inside and outside of fitting, push pipe together
95
what device control the intervals at which effluent is discharged to a gravity fed distribution field?
Ans: - Bell and Siphon
96
What additional equipment is required at the END of the building plastic ( Polyethylene ) water service suitable for cold water application?
Ans: - Check Valve come with diaphragm Tank
97
107) Plastic service pipe ENTERED at home, which valve we used?
Ans: - Globe valve / ball valve
98
108) Steam generator when connect with hot water, which p-trap is used? a) Thermo-dynamic b) Thermo-static
Ans: - Thermo-dynamic
99
109) Pipes for steam systems are commonly manufactured from ______ \_\_\_\_\_
carbon steel
100
Soil around the trench end how far need to throw away?
Ans: - 1 M ( 3’ )
101
Which copper joint we used underground? a) Copper tubes shall install underground approved flare, compression and brazed. b) . But Careful Compression fitting shall not be used underground, under a building.
Ans: - a) Copper tubes shall install underground approved flare, compression and brazed.
102
What is minimum and maximum trap arm of 2” shower?
Ans:- Minimum trap arm for 2” shower = 2d = 2x2 = 4” or 100mm Maximum trap arm for 2” shower = 2.4 Meter or 2400 mm
103
113) Where would be cleanout installed ( if required ) on a 6 storey rainwater leader? a) A cleanout is not required on leader b) Cleanout is only required upstream size of any offset over 1.5 c) On alternative storey with a maximum separation of 7.5 M d) Within 3m upstream of the bottom of the leader.
Ans: d) Within 3m upstream of the bottom of the leader.
104
114) What is suction line and drive line size?
Ans:- Suction line = 1-1/4” Drive Line ( Discharge line ) = 1”
105
We 1l/s = 31.7 fu = 900 L , what is the value of 2.5 l/s. a) 79.3 FU b) 2250 L
1 L/s = 31.7 Fu 2.5 L/s = 2.5 x 31.7 = 79.25 FU And 1 L/s = 900 L 2.5 L/s = 2.5 x 900 = 2250 L Answer is b) 2250 L
106
Number of TPI ( Thread per Inch ) on different size of pipe ? a) 1/16” to 1/8” = __ TPI b) ¼” to 3/8” = 18 TPI c) ½” to ¾” = 14 TPI d) 1” to 2” = 11-1/2” TPI e) 4” & above = 8 TPI
27
107
Number of TPI ( Thread per Inch ) on different size of pipe ? a) 1/16” to 1/8” = 27 TPI b) ¼” to 3/8” = __ TPI c) ½” to ¾” = 14 TPI d) 1” to 2” = 11-1/2” TPI e) 4” & above = 8 TPI
18
108
Number of TPI ( Thread per Inch ) on different size of pipe ? a) 1/16” to 1/8” = 27 TPI b) ¼” to 3/8” = 18 TPI c) ½” to ¾” = __ TPI d) 1” to 2” = 11-1/2” TPI e) 4” & above = 8 TPI
14
109
Number of TPI ( Thread per Inch ) on different size of pipe ? a) 1/16” to 1/8” = 27 TPI b) ¼” to 3/8” = 18 TPI c) ½” to ¾” = 14 TPI d) 1” to 2” = \_\_\_\_TPI e) 4” & above = 8 TPI
11-1/2”
110
Number of TPI ( Thread per Inch ) on different size of pipe ? a) 1/16” to 1/8” = 27 TPI b) ¼” to 3/8” = 18 TPI c) ½” to ¾” = 14 TPI d) 1” to 2” = 11.5 TPI e) 4” & above = __ TPI
8
111
What is a triple duty valve?
Ans: - One valve body that has a Check Valve, Shut off Valve and Balancing Valve.
112
What is Radon?
Ans: - Radon is an odourless, colourless gas, invisible that is found in the soil as a naturally occurring product of uranium decay
113
PVC 3” or 4” pipe used for Radon (gas).
114
Radon mitigation pipe used from under the basement through the foundation. ( means pipe used from underground to the outside in roof.
115
When Radon mitigation pipe install, where they install?
Ans: - Below the basement slab ( foundation )
116
) Some part of harness tier out, what need to do? a) Repair b) Give to someone c) Throw away ( not repair )
Ans:- c) Throw away
117
Unfiltered ( Hard ) water comes in house, what’s the reason?
Ans: - insufficient salt ( not cleaned properly )
118
15 lb of water, need to temp change 49 F to 190 F. How many BTU required?
Ans:- need to raise temp = 190 – 49 = 141 F 1 lb to raise 1 F required BTU = 1 BTU 15 lb to raise 1 F required BTU = 1 x 15 = 15 BTU 15 lb to raise 141 F required BTU = 15 x 141 = 2115 BTU So, 2112 BTU required 15 lb to raise 141 degree Fahrenheit.
119
Impeller works slow what’s reason?
Ans: - Tank have less pressure
120
130) Pump not work fully ?
Ans: - tank water logged
121
Pump need to lift up? a) Suction line, Suction up b) Impeller add
Ans: - B) Impeller add
122
Pump is doing Less Cycling, what’s the reason?
Ans: - Leaking in suction line
123
3 Zones on 3 storeys, No pressure, no heat anywhere?
Ans: - Expansion tank Failed
124
134) Why Pump loosing Prime? a) Plugged suction b) Leaking Suction c) Foot valve to low
Ans:- Leaking suction
125
Minimum supply tube Size ?
Ans: - 3/8”
126
Minimum inside diameter for supply pipe?
Ans; - 6.3 mm
127
Copper to cast iron, which fitting used?
Ans: - Di-electric , Mech Coupling
128
If the cycle of flush valve is long, how we fix that?
Ans: - turn the water screw anti-clock wise
129
If the cycle of flush valve is short, how we fix that?
Ans: - turn the water screw clock wise.
130
If the water continuous running on flush valve, what’s the reason?
Ans: - Orifice or Diaphragm blocked/ clogged
131
New person at work, does not under stand work, what he have to do? a) Check with supervisor b) No need to work c) Clarification from co-work d) Gives his work to some one else
ans:- confused with a & c
132
On water feed what install for storage tank? a) T & P relief valve b) Expansion tank
Ans: - Expansion tank
133
How PVC pipe Join?
Ans: - PVC pipe Cut , Bevel,
134
) Which welding permit required?
Ans: - hot work permit
135
Chiller need to install, what need with this?
Ans: - buffer tank
136
Two urinals are dual vented, find the vent size?
Ans: - Urinal washout type = 1.5 fu 2 Urinal washout type = 3FU D ual Vent = 1-1/4 ( 2.5.7.1 )