- And electric hot water tank with emerging elements is considered to be:
a. 70% efficient
b. 80% efficient
c. 90% efficient
d. 100% efficient
d. 100% efficient
- Instantaneous hot water heater:
a. Stores hot water instantly for future use
b. Heats the water after it leaves the system
c. Has a control valve that activates the burner when water is drawn
d. Is 100% efficient
c. Has a control valve that activates the burner when water is drawn
- Baffle is often placed in the flue passage of a centre flue hot water tank to:
a. Slow the exit of hot combustion gases
b. Prevent the tank from freezing
c. Help clean out the flue passage
d. Speed up the exit of hot combustion gases
a. Slow the exit of hot combustion gases
- Which of the following is not found on a T & P relief valve information tag:
a. Size of valve
b. BTU rating of hot water tank
c. Pressure setting
d. Sensor length
b. BTU rating of hot water tank
has btu rating of the valve but not HWT
- Stall urinals are:
a. Installed during the rough in stage
b. Prohibited by code
c. Placed so that the front lip or rim is slightly above the finish floor
d. Installed during the finishing stage
a. Installed during the rough in stage
- A single trap may serve a 3 compartment sink if it is:
a. The same size of as the fixture outlet pipes
b. One size larger than the largest fixture outlet pipe
c. No more than 900 mm from the furthest fixture outlet
d. Equipped with a union ring for removal
b. One size larger than the largest fixture outlet pipe
- A “TY” can be used to connect:
a. A fixture drain to a horizontal branch
b. Vent pipe to a horizontal branch
c. Vent pipe to another vent pipe
d. Both B and C
d. Both B and C
TY AKA san tee
- The vertical water distribution pipes in the building are referred to as
a. Stacks
b. Risers
c. Branches
d. Mains
b. Risers
- The water service pipe to a building should be:
a. Type K or L soft copper tube
b. Type K hard copper tube
c. Type L soft copper tube
d. Type K or L hard copper tube
a. Type K or L soft copper tube
- ABS or PVC horizontal piping must be supported at intervals not exceeding:
a. 3’
b. 4’
c. 5’
d. 6’
b. 4’
- An 1/8 bend refers to a cast iron fittings to change direction by::
a. 22 1/2°
b. 45°
c. 60°
d. 90°
b. 45°
- When installing a bypass for a pressure reducing valve it is best to use a:
a. Gate valve
b. Plug valve
c. Globe valve
d. Ball valve
c. Globe valve
- BCuP brazing alloy maybe used to join copper tube to copper fittings:
a. Only a flux is also used
b. Only if the copper tube is hard drawn
c. Without using flux
d. Without exceeding 800°F
.
c. Without using flux
- The most common cause of the collapse of the hot water tank is:
a. Vacuum
b. Excessive heat
c. Excessive pressure
d. Rough handling
a. Vacuum
- A pipe full of water 52 feet high would produce the pressure, at a point 10 feet up from the bottom, of approximately:
a. 4.33 psi
b. 18.2 psi
c. 22.5 psi
d. 62.4 psi
b. 18.2 psi
42 x .433
- What would be the most correct definition of total force?
a. total weight of water divided by surface area
b. weight of water times surface area
c. weight of water per square inch
d. pressure divided by surface area
b. weight of water times surface area
- The max length of a disposal field lateral, according to the BC Health Act:;
a. 50’
b. 75’
c. 100’
d. 150’
c. 100’
- A pressure tank’s main purpose, when used in a rural water supply system, is to:
a. stop water hammer
b. allow the water to settle before use
c. purify the water before use
d. prevent cycling of the pump
d. prevent cycling of the pump
- The actual lift of a pump is less than the theoretical lift. This is caused by
a. The loss of efficiency due to friction
b. the inability of the pump to create a perfect vacuum
c. the changes in atmosphere pressure above sea level
d. all of the above
d. all of the above
- The minimum diameter for a water service is:
a. 1/2”
b. 5/8”
c. 3/4”
d. 1”
c. 3/4”
- Threaded drainage fittings installed in a vertical stack are tapped to provide:
a. for a short alignment of branch lines
b. for a short thread engagement
c. a pitch of 1/8” lift
d. a pitch of 1/4” lift
d. a pitch of 1/4” lift
- A combined sewer service carries:
a. storm sewage and groundwater
b. sanitary and storm sewage
c. sanitary sewage and clear-water waste
d. sanitary and groundwater
b. sanitary and storm sewage
- The max fall on a trap arm from the weir to the vent is :
a. 1 pipe diameter
b. 2 pipe diameter
c. 1/4” per foot
d. 1/2” per foot
a. 1 pipe diameter
- The vertical distance between the trap weir and the trap dip is the:
a. vent relief distance
b. trap dip
c. revent distance
d. trap seal depth
d. trap seal depth
- The pluming fixture with the greatest fixture unit water demand is:
a. urinal valve
b. public WC flush tank
c. private WC flush tank
d. public WC flush valve
d. public WC flush valve
- The developed length of a branch vent shall be:
a. from its upper end to its connection to the lowest vent pipe
b. from its upper end to a connection point a min 6” above the flood level rim of the closest fixture
c. from its upper end to a point 6” above the flood level rim of the farthest fixture
d. from its upper end to the farthest downstream fixture that it serves
d. from its upper end to the farthest downstream fixture that it serves
- an ordinary displacement-type water meter registers:
a. the rate of flow through the meter
b. the velocity of flow through the meter
c. the capacity of the meter
d. the total flow through the meter
d. the total flow through the meter
- Which of the following meters is two meters in one?
a. turbine
b. displacement
c. oscillating piston
d. compound
d. compound
- To prevent a load of pipe that is being lifted from swinging:
a. a double sling is used
b. a double cable is used
c. a tag line is used
d. a pipe strap is used
c. a tag line is used
- The max surface temp that a hot water radiant floor heating panel should not exceed is:
a. 80 to 100°F
b. 100 to 140°F
c. 160 to 180°F
d. 180-200°F
a. 80 to 100°F
- On a deep well convertible jet pump, the suction line is:
a. the same as the drive line
b. larger than the drive line
c. smaller than the drive line
d. not required
b. larger than the drive line
- An ejector nozzle in a deep well convertible jet pump causes water from the well to flow into the ejector by:
a. ejector nozzles are not used in pumps
b. increasing the pressure in the ejector venturi
c. decreasing the pressure in the ejector venturi
d. decreasing the velocity of the water
c. decreasing the pressure in the ejector venturi
- The pitless adapter is located in the:
a. well casing
b. well casing below the frost line
c. well casing below the ejector
d. well casing below the standing water line
b. well casing below the frost line
- This control used on a hot water heating system adjusts the boiler water temperature by measuring the outside air temperature:
a. outdoor reset control
b. aquastat
c. thermostat
d. temperature limit control
a. outdoor reset control
- This pipe hanger is best suited to allow pipe movement due to heating and cooling of the pipe:
a. roller hanger
b. clevis hanger
c. ring hanger
d. strap hanger
a. roller hanger
- This valve can modulate water temperature in a hydronic heating system:
a. balancing valve
b. bypass valve
c. pressure regulating valve
d. mixing valve
d. mixing valve