Fourth Year - Plumbing Interprovincial Practice Exam 1[][][][][][][][][][][][][][][][][][][][][][] Flashcards
You are required to use a 20 foot ladder placed up against a building that is 40 feet high. At what horizontal distance from the base of the building must the ladder be?
A. 4’.
B. 5’.
C. 6’.
D. 7’.
B. 5’.
Confined spaces are hazardous environments because they usually have:
A. Explosive atmospheres.
B. Restricted access and egress.
C. Flood hazards[][][][][][][][][][][][][][][]
D. Limited room for maneuverability.
B. Restricted access and egress.
Scaffolding erected __ feet above the ground must have guard rails.
A. 4.
B. 6.
C. 8.
D. 10.
D. 10.
Class “A” fire extinguishers are used on and contain:
A. Flammable liquids. CO².
B. Metal. CO²[][][][][][][][][][][][]
C. Electrical components. Foam.
D. Combustable material. Water.
D. Combustable material. Water.
When using a Hilti powder actuated fastening tool, the device fails to fire when the trigger is pulled. The first thing you should do is?
A. Keep the tool in position and wait 30 seconds.
B. Remove the cartridge[][][][][][][][][][][][][][][][][][][][][][][]
C. Inspect the magazine[][][][][][][][][][][][][][][][][][][][][][][]
D. Depress the trigger again[][][][][][][][][][][][][][][][][][][]
A. Keep the tool in position and wait 30 seconds.
Referring to the figure below, determine how many 90° fittings would be required to construct the piping arrangement.
A. 4.
B. 5.
C. 6.
D. 7.

A. 4.
How many 2” pipes does it take to equal the volume capacity of a 6” pipe?
A. 2.
B. 5.
C. 7.
D. 9.
D. 9.
When using oxy-fuel cutting and welding equipment, a flashback arrestor protects the operator from?
A. Flame traveling into the hoses.
B. Bright flashes[][][][][][][][][][][][][][][]]
C. Electrical shock[][][][][][][][][][][][][]]
D. Material blowback[][][][][][][][][][][]
A. Flame traveling into the hoses.
Horizontally run 3/4” type M copper pipe must be supported every:
A. 1 meter.
B. 1.2 meters.
C. 2.5 meters.
D. 3 meters[][]
C. 2.5 meters.
Referring to the figure below, find the depth of the pipe invert at dimension X.
A. 1.85 m.
B. 1.90 m.
C. 1.95 m.
D. 2.00 m.

C. 1.95 m.
Water that is determined to have a pH of 5.5 would be considered:
A. Mildly alkaline.
B. Very alkaline[]]
C. Very acidic[][][]
D. Mildly acidic[]]
D. Mildly acidic.
Which type of copper tube is permitted for underground water distribution?
A. Type M soft.
B. Type L soft[]
C. Type K soft[]
D. DWV[][][][][][]
C. Type K soft.
Which is not an approved method for joining cast iron waste pipe?
A. Compression joint.
B. Welded joint[][][][][]]
C. Mechanical joint[][]
D. Caulked joint[][][][]]
B. Welded joint.
Dielectric unions are used to:
A. Ground metallic pipe.
B. Connect plastic to copper pipe.
C. To prevent shocks[][][][][][][][][][][][]]
D. Prevent corrosion[][][][][][][][][][][][]]
D. Prevent corrosion.
When installing glass piping, if one end needs to be field cut the ends should be joined?
A. Plane to plane.
B. Bead to bead[]
C. Bead to plane[]
D. Bead to hub[][]]
C. Bead to plane.
Bell and spigot cast iron is installed with the:
A. Bell upstream.
B. Spigot upstream.
C. Bell downstream.
D. Doesn’t matter[][]
A. Bell upstream.
What force would be exerted on the gate of a closed 6” gate valve if the water pressure acting on it measured 46 psig?
A. 867 pounds.
B. 1300 pounds.
C. 2604 pounds.
D. 5202 pounds.
B. 1300 pounds.
Asbestos cement pipe installed below a 60mm thick concrete floor must be at least how deep?
A. 150 mm.
B. 300 mm.
C. 600 mm.
D. 1200 mm.
C. 600 mm.
What is the maximum practical suction lift of a shallow well jet pump?
A. 22’.
B. 25’.
C. 29’.
D. 33.9’.
B. 25’.
A backwater valve may be installed in a building drain provided that it is:
A. Properly vented.
B. Normally open[]]
C. 3” or larger[][][][]]
D. Trapped upstream.
B. Normally open.
This discharge from a sump pump shall have the following fittings installed in order; in the direction of flow:
A. Check valve, union, shut-off valve.
B. Shut-off, coupling, check valve[][][]
C. Check valve, shut-off valve, union
D. Union, check valve, shut-off valve.
D. Union, check valve, shut-off valve.
When a well pump turns on as soon as a faucet is used the most likely problem is:
A. Water logged pressure tank.
B. Defective pressure switch[][]
C. Foot valve not holding[][][][][]]
D. Pump impellar is worn out[][]
A. Water logged pressure tank.
A 4” cast iron pipe with 1” insulation is to pass through a wall. How large a diameter hole is required to be cut? Allow for a 1/4” air gap.
A. 5”.
B. 5.5”.
C. 6”[][]
D. 6.5”.
D. 6.5”.
A gear pump is a positive displacement pump and must be installed with a:
A. Pressure tank.
B. Pressure switch.
C. Pressure relief valve.
D. Pressure reducing valve.
C. Pressure relief valve.