Cleanouts Flashcards
2) a cleanout fitting shall be provided on the upstream side and directly over every _______ trap
Running
3) interior leaders shall be provided with a cleanout fitting at the bottom of the lear or not more that __m upstream from the bottom of the leader
3m
4) where a cleanout is required on a building sewer __ inches or larger in size, it shall be a manhole
8”
5) a buildong sewer shall not change dirextion or slope between the building and public sewer or between cleanouts, wxcept that pipes not more than __ inches in size may change dirextion
a) by not more than __ degrees every __m
6”
5 degrees
3m
5) a buildong sewer shall not change dirextion or slope between the building and public sewer or between cleanouts, wxcept that pipes not more than __ inches in size may change direction
B) by the ise of fittings with a cumulative change in direction of not more that ___ degrees
45
6) building drains shall be provided with a cleanout fitting conforming to …. That is located as close as practical to the place where the _____ drain leaves the building
Building
7) soil or waste stacks shall be provided with a cleanout fitting at the ____ of the stack
Bottom
soil or waste stacks shall be provided with a cleanout fitting not more than _ m upstream of the bottom of the stack
3m
Manhole needs
A ridgid ladder of corrosion resistant material where depths exceed __m
1
The piping between a cleanpit fitting and thr drainage system it serves shall not change direction by more than ___ degrees
45
There shall be no change of dirextion between a cleanout fitting and thr ____ that it serves
Trap
Cleanouts serving fixtures where contamination of body fluids is likely, shall be located a min of ____ mm above the flood level rim
150mm