Cleanouts Flashcards

1
Q

2) a cleanout fitting shall be provided on the upstream side and directly over every _______ trap

A

Running

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

3) interior leaders shall be provided with a cleanout fitting at the bottom of the lear or not more that __m upstream from the bottom of the leader

A

3m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

4) where a cleanout is required on a building sewer __ inches or larger in size, it shall be a manhole

A

8”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

5) a buildong sewer shall not change dirextion or slope between the building and public sewer or between cleanouts, wxcept that pipes not more than __ inches in size may change dirextion
a) by not more than __ degrees every __m

A

6”

5 degrees

3m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

5) a buildong sewer shall not change dirextion or slope between the building and public sewer or between cleanouts, wxcept that pipes not more than __ inches in size may change direction
B) by the ise of fittings with a cumulative change in direction of not more that ___ degrees

A

45

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

6) building drains shall be provided with a cleanout fitting conforming to …. That is located as close as practical to the place where the _____ drain leaves the building

A

Building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

7) soil or waste stacks shall be provided with a cleanout fitting at the ____ of the stack

A

Bottom

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

soil or waste stacks shall be provided with a cleanout fitting not more than _ m upstream of the bottom of the stack

A

3m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Manhole needs

A ridgid ladder of corrosion resistant material where depths exceed __m

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The piping between a cleanpit fitting and thr drainage system it serves shall not change direction by more than ___ degrees

A

45

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

There shall be no change of dirextion between a cleanout fitting and thr ____ that it serves

A

Trap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Cleanouts serving fixtures where contamination of body fluids is likely, shall be located a min of ____ mm above the flood level rim

A

150mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly