Hangar Familiarization
What is The Hangar designed for?
- Provides and environmentally protected area to perform maintenance on aircraft
- Stores the aircraft away from the weatherdecks
How many Hangars are used in Naval Aviation (Shore Stations)?
There are three types of Hangars
What is a Type 1 maintenance hangar designed for?
Carrier Aircraft
What is a TYpe 1 hangar configured for?
- Strike Fighter Squadron
- 2 Carrier Airborne Early Warning Squadrons or a Helicopter antisub warfare squadron
What are the dimensions of a type 1 hangar?
235 ft wide 85 ft deep
What is a type 2 Hangar designed for?
For US Marine Corps Aviation
What type of aircraft was a type 2 Hangar configured for?
- CH-53 Helicopters
- V-22 Ospreys
- C-130 Hercules
What are the dimensions of a type 2 Hangar?
325 ft wide x 119 ft deep
What is a type 3 maintenance hangar designed for?
Land based Patrol/ Large Transport aircraft
What are the dimensions of a type 3 hangar?
165ft wide x 165ft deep
What must be kept clear at all times in a shore based hangar?
Painted red fire lane adjacent to bulkhead that divides the hangar from the maintenance workcenters
Where are Portable CO2 Fire extinguishers’ located in a shore based hangar?
They are mounted on the bulkhead above the deck
What does the aircraft electrical system with cords provide?
Applies external electrical power to the aircraft
What is used for securing access and sealing off the elements of a shore based hangar?
Manually or automatically operated hangar doors
What provides a 100 ohm or less point to ground/discharge stray voltage?
Aircraft Ground
Where are Aircraft Grounds located?
On a pattern or grid through the hangar deck
Aircraft stored inside can cost up to how many times the cost of the building they are stored in?
10 times the amount
What are the Hangar protection requirements for high value aircraft?
- Low level AFFF system with low profile nozzles designed for high reliability with low maintenance
- Closed head water only overhead sprinkler system designed to protect the building and provide cooling
- Optical detection system to activate low level AFFF system
- Appropriate drainage systems to limit any spill pool size/contain AFFF
- Draft curtains, to prevent cooling of sprinklers allowing for earlier detection
What is the estimated cost for a false activation of the fire suppression system?
Approxiamtely $80,000
The estimated cost would be due to what?
- Damage to Aircraft
- Cost to recharge the system
- Cost to run-off retention
- Cost of AFFF removal
- Associated manpower expenses
What do hangars serve as onboard aviation capable ships?
Maintenance area and Storage area
What are the largest hangars?
Aircraft carrier Hangars
What are the dimensions of aircraft carrier hangars?
110ft wide by 685 ft long and 25ft overhead clearance
What is the actual storge space of an Aircraft Carrier Hangar?
1.4 acres