OXYGEN SYSTEM Flashcards

1
Q

How is oxygen flow indicated?

A

By the yellow flow indicator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the significance of the OXY ON white flag and the TEST slide?

A

When the left door opens, the mask is supplied with oxygen. Mask is still supplied when the door closes. The OXY ON flag will be visible. Press the slide to TEST and RESET oxygen flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How is emergency oxygen tested (flow under pressure)?

A

Pressing the EMERGENCY knob

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What happens when you squeeze the red clips on the oxygen mask?

A

It unlocks the two doors and infalates the harness

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How does the overpressure selector on the mask work?

A

Overpressure is supplied automatically above 30’000 ft
Overpressure is only available when the NORM/100% selector is set to the 100% position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What does an amber “OXY” indication mean on the DOOR/OXY page?

A

Pressure is below 400 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What does a half boxed amber indication around the oxygen psi number on the DOOR/OXY page mean?

A

Pressure is below 1200 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the oxygen pressure distributed to the masks?

A

80 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What two things will cause the blow out disc to blow out for high oxygen pressure?

A

2500-2775 psi high pressure from the cylinder
175 psi of regulator pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How do you test the oxygen mask and the mic?

A

Crew supply switch ON
INT pb on
Loud speaker on
INT switch to INT
Selector to 100%
Press the “PRESS TO TEST AND RESET” slider to see the blinker turns yellow and then goes black
Press “PRESS TO TEST AND RESET” + “PRESS TO TEST” and check that the blinker stays yellow for as long as the button is pressed. You should also hear oxygen flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the function of the EMERGENCY pressure selector on the oxygen mask?

A

To create overpressure and clear smoke and condensation in the mask

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What does a REGUL LO PR message mean?

A

Distrubution pressure to the mask in below 50 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is your action if oxygen pressure indication is below 1200 psi?

A

Consult FCOM to check pressure required for flight is sufficient

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

At what cabin altitude does the oxygen masks drop in the cabin?

A

Approximately 14’000 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If automatic deployment of the oxygen masks fails, what other methods can be used to deploy them?

A

Push the MASK MAN ON pb
Use the manual tool in the cabin to manually release them

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How many crew oxygen bottles are there?

A

One

17
Q

What is the minimum oxygen pressure for the crew?

A

1300 psi

18
Q

How long will chemical oxygen masks supply oxygen?

A

For 15 min

19
Q

What happens when you during pre-flight extinguish the CREW SUPPLY OFF light?

A

It electrically opens a valve in the avionics bay to supply low pressure crew oxygen

20
Q

What would you notice on the DOOR/OXY page when you push to extinguish the CREW SUPPLY OFF light?

A

The OXY would turn amber from the original green indication

21
Q

Above what altitude will the crew oxygen masks provide 100% oxygen regardless of the position of the NORM/100% selector?

A

Above 35’000 ft

22
Q

Will the crew oxygen mask microphone automatically deactivate when the mask is stowed back after use?

A

No, you must press the RESET slide switch?

23
Q

If the PASSENGER SYS ON light is on, does that mean that all the passenger masks have dropped?

A

Not necessarily, the cabin crew might have to use the manual release tool to get some masks to deploy

24
Q

How does the passengers activate the flow of oxygen to their masks?

A

By pulling the mask towards themselves

25
Q

What is the purpose of the portable oxygen system?

A

To provide first aid oxygen but also to allow the cabin crew to move around the cabin if needed

26
Q

What should you notice on the DOOR ECAM when you extinguish the CREW SUPPLY OFF light?

A

The OXY indication should change from amber to green