NAVEDTRA 14188A, NEETS Mod. 16, Ch. 1 Flashcards

1
Q

Which system is used by all branches of the military to identify equipment by a system of standardized nomenclatures? 


A

Joint Electronics Type Designation System (JETDS)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which year was the Electronic Test Equipment Classification Board established to control the increased use of undesirable electronic test equipment (ETE) in fleet and shore activities?

A

1973

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Which command manages general purpose electronic test equipment?

A

Space and Warfare Systems Command (SPAWARSYSCOM)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which type of test equipment has the capability, without modification, to generate, modify, or measure a range of parameters of electronic functions required to test two or more equipments or systems of basically different design?

A

GPETE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What was specifically designed to generate, modify, or measure a range of parameters of electronic functions of a specific or peculiar nature required to test a single system or equipment? 


A

SPETE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What has the responsibility for evaluating requests to purchase nonstandard GPETE and for recommending its approval or disapproval to NAVSEA?

A

NESEA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which program was designed to keep track of all installed and portable equipment in the fleet?

A

(MSCLSIS)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which two basic elements does the SCLSIS program have?

A

Validation and Inventory updating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the checking, adjusting, or systematically aligning a test instrument to a known standard known as?

A

Calibration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which label has black lettering on a white background that comes in two sizes and is the most commonly used label in the METCAL program?

A

Calibrated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which label has red lettering on a white background and is used when you must know the actual measurement values to use the instrument?

A

Calibrated – Refer to report

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which labels or tags are used when some unusual or special condition in the calibration should be drawn to your attention and have black letters on a yellow background?

A

Special calibration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which label has black lettering and a white background and is affixed when the calibration is performed by the user? 


A

User calibration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Which label has green lettering and a white background and is used in the event that an individual instrument due for recalibration will not be used for some time in the future?

A

Inactive-calibrate before use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which label has black letters and a red background and is attached to an instrument that fails to meet the acceptance criteria during calibration and cannot be adequately repaired?

A

Rejected-Refer to attached tag

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Which label has black letters on a white background that is placed over readily accessible (usually exterior) adjustments to prevent tampering by the user when such tampering could affect the calibration?

A

Calibration-void if seal is broken

17
Q

Which IMA policies purpose is to streamline the procedure and cut down delays in returning your equipment to you calibrated and ready to use?

A

No reject

18
Q

Which data processing system was designed to provide a standardized system for the recall and scheduling of test, measurement, and diagnostic equipment (TMDE) into calibration facilities?

A

Measure

19
Q

Who oversees the MEASURE program and establishes policy and guidelines?

A

Chief of Naval Operations

20
Q

Which type of work is done to correct, reduce, or counteract wear, failure, and damage to equipment?

A

Maintenance

21
Q

Which two main categories is the maintenance of electrical and electronic equipment divided into?

A

Preventive and Corrective

22
Q

Which term refers to the initial operating conditions of the equipment on installation or after overhaul when it is operating according to design?

A

Baseline

23
Q

To prevent damage to electrical measuring instruments, you should observe the precautions relating to three hazards: mechanical shock, exposure to magnetic fields, and what else?

A

Excessive current flow

24
Q

Which measurement charts, usually found in equipment technical manuals, contain the normal operating voltages found in the various stages of the equipment?

A

Point-to-point voltage

25
Q

Which capacitor property is important because it is an indication of the various losses of a capacitor?

A

Power factor

26
Q

What can be used to measure capacitance, inductance, and resistance for precise accuracy?

A

AC Bridges

27
Q

Which type of bridge is used for precise measurement of resistance?

A

Wheatstone