How do we move power at LOW POWERS (1 x 10-3% to 2%)?
CEA’s
How do we move power from 2% to 14%?
Dilution or CEA’s
How do we move power above 20%?
Dilution
During swapover, what should we expect from TAVG, SG Pressure, PZR Pressure and SG Level?
A momentary Decrease (Shrink in SG)
Why are the FW Economizer lines warmed up prior to increase in power to 12%?
Minimize Shrink and Swell (and help control RX changes)
Why is only ONE FWIV opened at a time?
TS 3.7.3 Operability
Drains accumulator pressure (CTMT isolation)
How do we perform swapover in MANUAL?
Stabilize power 13.5-14.5%
BOTH SG Downcomer Ctrl valves in AUTO
BOTH Econ controllers in MANUAL with zero output
Slow open Econ valves, Downs modulate closed
WHEN both DOWNS closed, raise power to 18-19%
Place BOTH ECONS in AUTO
Why do we raise Main Generator load as soon as we SYNC?
To avoid Reverse Power Trip
>50 MW for minimum of 30 seconds
What is the minimum allowed load for normal operations for the Main Generator?
5% of rated load (can erode last stage buckets)
10% is recommended (Exhaust Hood temps)
Why do we not want to run at FULL SPEED NO LOAD conditions on the Main Turbine?
> 1 hour increases RUB chances
Less than 410MW and vacuum 4-5”HgA is allowed for how long?
1 hour maximum
If vacuum is > 5”HgA, can we operate the Main Turbine?
NO
At BOL, with high back pressure on the Main Turbine, what can occur with the RCS?
SHRINK (cooldown)