IRPI Flashcards
IRPI power supply for rod bottom B/S, bypass B/S, and racks and modules
PP-61 circuit 1
(480V Bus 5 feeds MCC-15 which feeds PP-61)
IRPI RTGB LED’s power supply
IB-7A circuit 10
IF you loos IB-7A what happens?
RTGB IRPI LED’s extinguish, but Rod Bottom bistable lights will still illuminate if rod drops
If you loose PP-61 what happens?
LED indicators on RTGB will default to “0” steps/inches, GREEN indications.
Rod bottom mistable light will not illuminate
LCO 3.1.4 Rod Group ALignment LImits
Rod Alignment Requirments for ITS
(For bank demand positions >=200 steps)
Each rod shall be within 15inches of its bank demand position
LCO 3.1.4 Rod Group Alignment limits
Rod Alightment requirements
(For bank demand postions <200 steps)
Each rod shall be within 7.5 inches of the average of the individual rod positions in the bank
A dropped Rod is still operable
A stuck rod is not operable
LCO 3.1.4 Rod Group Alignment LImits
For condition A
(One or more rods inoperable)
- Verify SDM within limits in the COLR (1 hour) or
- Initate boration to restore SDM within limits (1 hour) and
- Be in MODE 3 (6 hours)
3.1.4 Rod Group Alignment limits
For condition B
(One rod not within alignmnet limits)
- Restore rod to alignment (1 hour) OR
- Verify SDM within limits in COLR (1 hour) OR
- 3Initate boration to restore SDM to within limits (1 hour)
How many steps on RTGB for step counters
0-250 steps
Each step is how many inches
5/8”
Rod Bottom Bypass Bistables allows you to do what?
Allows you to operate below 35 steps without giving Rod Bottom alarm (20 steps)