Hydraulics Flashcards

1
Q

What happens to the EDP after an engine flame out?

A

In the event of engine flameout, the FADEC automatically commands the unload of the respective EDP, which reduces the hydraulic system pressure. This depressurization reduces the torque loads on the engine and facilitates a windmill restart (812 14-11-10 Pg 2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What facility does Hydraulic System 2 have on the ground with the electric pump switch in AUTO?

A

Same functions as Hyd 1 System (812 14-11-10 Pg 2) During landing operations, the Electric Hydraulic Pumps remain activated for 60 seconds to avoid abrupt hydraulic pressure variations in an event of engine failure. ACMP active if Flaps selected to any position greater than 0° and:

  • Thrust levers set to takeoff thrust, or
  • Ground speed greater than 50 kt.

During takeoff when thrust levers are set to TOGA, the Electric Hydraulic Pumps will be activated for 60 s to avoid abrupt hydraulic pressure variations in an event of engine failure.

PLUS (B12 14-11-10 Pg 5)

Electric Hydraulic Pump 2 will be automatically activated when the following conditions occur.

  • Engine 1 running and parking brake released;
  • During Engine 1 start (once N2 reaches 40%) if parking brake has been applied within the last 6 min.

NOTE: The Electric Hydraulic Pump 2 will be automatically turned off after 6 min have elapsed from parking brake application.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the system logic for operation of PTU?

A

Automatically started when all the following conditions are met:

  • Flaps not set to zero or Landing Gear not up and locked;
  • EDP 1 not fail;
  • Hydraulic reservoir 2 quantity above 12%.

PTU will not be activated if the airplane is on ground. (81214-11-10 Pg 5 & 6)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Why are the pump un-loader/ flow limiter valves fitted to System 3?

A

Hydraulic system 3 has two dedicated valves (Pump Un-Loader & Flow Limiter Valves) which are used only in an electrical emergency to avoid overload in the RAT. (812 14-11-10 Pg 8)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In flight, with AUTO selected, when will system 1 and 2 electric hydraulic pumps come on?

A

In flight, with the selector knob set to AUTO position, the Hydraulic System logic activates the electric pump in case of:

EDP or engine fail, or

Flaps selected to any position greater than 0°. (812 14-11-10 Pg 3)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Other than system load transience, what does the System 3 Hydraulic Accumulator do?

A

In an Electrical Emergency, the Hydraulic System 3 accumulator will provide hydraulic power to the associated flight controls from the beginning of RAT deployment until the ACMP 3A is powered by the AC ESS BUS. (B12 14-11-10 Pg 8)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When will the fluid shut off valves be closed and how?

A

If the fluid temperature reaches 125°(, the shutoff valve (SOV) automatically actuates. In the event of hydraulic system overheat (fluid temperature above 145°(), the HYO 2 OVERHEAT EICAS warning message will be displayed. In this case, the SOV can be manually actuated through a guarded pushbutton on the hydraulic system control panel. (B12 14-11-10 Pg 2 & 4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Why does System 3A pump only have a two-position Electric Hydraulic Pump 3A (ACMP 3A) is the primary power source switch?

A

Electric Hydraulic Pump 3A (ACMP 3A) is the primary power source for Hydraulic System 3 and it is powered by the AC ESS BUS. There is no automation associated with this pump. So in normal operation, the flight crew will turn the pump ON and OFF during engine start and shut down, respectively. (812 14-11-10 Pg 7)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the indication of an EDP failure?

A

HYO 1 (2) EDP FAIL on EICAS (812 14-11-15 Pg 1) plus associated indications (grey circle and a white windmill beneath an amber cross) on the MFD Hydraulic Synoptic Page (B12 14-11-05 Pg 6)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What provides positive pressure for the reservoirs?

A

A mechanical piston pressurizes the hydraulic system reservoirs, which supply fluid to the pump. (B12 14-11-10 Pg 2 & 4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Inbound and Outboard brakes hyd systems and what’s buses

A

Hyd 1 out DC ESS BUS 1
Hyd 2 in DC ESS BUS 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

4 BCM Functions

A

Antiskid
Touchdown
Locked wheel
Automatic wheel braking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the purpose of the Pump Unloader Valve (PUV) during RAT deployment? What is the role of the Flow Limiter Valve (FLV)?

A

The PUV reduces pressure during RAT startup to decrease the electrical power required.

The FLV reduces flow to lower electrical power demands on Pump 3A during RAT deployment.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When does the PTU (Power Transfer Unit) activate automatically (AUTO switch position)?

A

The PTU activates automatically when:

ENG 2 or EDP 2 fails,

Flaps are extended or the landing gear is not up and locked,

EDP 1 is operational,
and

Hydraulic reservoir 2 is above 12%.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Under what condition does Electric Pump 3B run automatically?

A

Pump 3B runs automatically only when Pump 3A fails, not due to engine or EDP failure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

At what temperature does a hydraulic fluid overheat trigger the automatic shutdown of pumps?

A

At 125°C, EDP 1(2) SOV closes, and Pumps 3A & 3B shut off unless an electrical emergency exists.

At 145°C, EDP 1(2) SOV can be manually closed, and Pumps 3A & 3B can be manually shut off.

17
Q

When does an automatic AC Electric Pump 1 (or 2) run on the ground?

When will electric hydraulic pump 2 also be automatically activate on the ground?

A

flaps are extended to any position greater than 0 deg

and

Thrust is set to TOGA or Airspeed is greater than 50kts

Also for electric pump 2 on the ground:

  • Engine 1 running and parking brake released
  • During Engine 1 start (once N2 reaches 40%) if parking brakes has been applied within the last 6 mins
18
Q

How is System 3 hydraulics powered during RAT deployment?

A

System 3 hydraulics are powered by an accumulator while the RAT deploys. PUV and FLV reduce Pump 3A’s electrical demand.

19
Q

What triggers the automatic operation of AC Electric Pumps in flight?

A
  • EDP or engine fail
  • Flaps selected to any position greater than 0 deg
20
Q

During landing operations, the electric hydraulic pumps remain activated for how long?

A

60 seconds

21
Q

What does Hydraulic system 3 control?

A
  • Elevator (Right hand outboard actuators)
  • Rudder (lower actuator)
  • Ailerons (Left and right outboard actuators)
22
Q

What happens during an electrical emergency condition with hydraulic system?

A

Overheating protection system will be inhibited preventing the pumps from being turned off automatically.

23
Q

When the aircraft is ready for T/O which hydraulic pumps will be activated?

A

Electric Pumps 1 and 2 automatically when flaps are extended >0 and TLAs set to T/O or ground speed > 50 kts

24
Q

Which Flight control surfaces are supplied by Hydraulic System 3?

A

Elev OutBd RH, Rud lower, Ail OutBd

25
Q

Which valves are allowed to OPEN and CLOSE to allow the RAT to run up faster to its operational speed on deployment, and prevent RAT stalling?

A

OPEN = Pump unloader Valve (PUV) CLOSED = Flow Limiter Valve (FLV)

26
Q

When the aircraft is ready for landing which hydraulic pumps will be activated?

A

1 and 2 are automatically ON when flaps are > 0 and operate for 1 minutes after landing Airspeed is below 50 kts

27
Q

If the hydraulic fluid reaches a temp of 125C what will happen to Hyd system 1 or 2?

A

The SOV automatically actuates, thus isolating the EDP from the hydraulic flow line

28
Q

Main components of the Hyd system?

A

2 EDP, 4 Electric pumps, 1 PTU, 3 Reservoirs

29
Q

Under what normal conditions is the electrical hyd pump used?

A

T/O and Landing, and in case of an engine or engine driven pump failure

30
Q

Hyd pump selector knobs AUTO when will they switch on?

A

1 and 2 are ON when the respective EDP or engine fails OR if flaps are selected to any position greater than 0 deg