What are the ratings of the IDGs and APU?
Engine IDGs and the APU Generator are rated at 40kVA, 115VAC, 400Hz (3 Phase) (B12 14-05-10 Pg 1).
What normally supplies AC ESS bus?
AC BUS 2 (B12 14-05-40 Pg 2)
What are the alternate and emergency supplies for the AC ESS bus?
Alternate: AC BUS 1. Emergency: RAT (electrical emergency) (B12 1405-40 Pg 2)
When will the RAT deploy automatically?
Whenever AC power sources are not powering AC buses, the RAT is automatically deployed, and after 8 s, supplies power to the AC ESS BUS. (B1214-05-10 Pg 4)
Where is the battery voltage displayed?
On the MFD Electrical Synoptic Page (B12 14-05-05 Pg 7) and the MFD Synoptic Status Page (B12 14-05-05 Pg 12)
In an ELECTRICAL EMERGENCY with the RAT failed, for how long will the batteries supply essential systems?
In an ELECTRICAL EMERGENCY, while the RAT is not fully deployed and also if RAT stall speed is reached, batteries supply essential loads for 10 min. (B12 14-05-15 Pg 2)
What indications will be seen when the Battery temperature rises above 70 degrees C for longer than 2 seconds?
Whenever the battery temperature reaches 70°C for at least 2 s, the associated indication becomes red and the EICAS WARNING message BATT 1 (2) OVERTEMP is triggered. (B12 14-05-15 Pg 2)
What is the minimum IAS for RAT operation?
130 kt is required to ensure the RAT continues supplying AC/DC ESS BUSES. (B12 14-05-10 Pg 4)
In flight on battery power only, which electrical busses may be powered?
HOT BATT BUS 1, HOT BATT BUS 2, APU START BUS, DC ESS BUS 1/2/3, AC STBY BUS (via DC BUS 1 and DC INVERTER) (B12 14-0540 Pg 5)
What does the avail light on the electrical overhead panel mean?
Illuminates inside the button when the AC GPU is connected to the airplane and AC power quality requirements (voltage/amperage/frequency) are satisfied. (B12 14-05-05 Pg 3). Ground staff can connect the GPU directly to the AC/DC GND SVC BUSES for ground maintenance and flight preparation, by pushing the respective button located on the front ramp panel or on the flight attendant panel at the forward right galley. (B12 14-05-10 Pg 3)
What is No Break Power Transfer (NBPT)?
The E-Jets Electrical System has a protection feature, the NBPT, which avoids electrical transient in case of power transfer when the airplane is on the ground. The NBPT allows the momentary paralleling between two AC power sources: the IDGs, GPU and the APU generator, at any possible combination.
After achieving the auto-parallel condition, the system is able to parallel the sources for a short period (milliseconds). If the system does not achieve the auto-parallel requirements within the allowed time delay, the transfer will be concluded with a break-transfer of minimum power interruption. (B12 14-05-10 Pg 5)
What is the rating of the RAT? What hydraulic pump does it power?
15kVA, 115 V AC, 400Hz
ACMP 3A
What does the AC system compose of?
- 2 IDGs
- 1 APU
- 1 Inverter
- 1 RAT
- 1 external AC receptacle
What does the DC system compose of?
- 2 NiCd batteries
- 3 TRUs
- 1 APU external DC receptacle
What conditions cause the IDG amber LED to illuminate indicating that the IDG needs to be disconnected? When does automatic IDG disconnection occur?
How long should the switch be held in this position to disconnect the IDG?
Oil pressure - below 140 psi +/- 25 psi
Oil Temperature - 335F +/- 10F (168C +/- 5C)
Automatic disconnection - Oil temp reaches 366F (185.6C)
1 Second