HRFPMD Flashcards
1ST TRUCK
recall elevators
2nd truck
2ND ROOF- LSR
ensure elevators recalled and searched
control ventilation on all other areas aside fire apt. as DIRECTED BY IC
SEARCH PUBLIC HALL AND ENSURE ALL EVACUATION STAIR DOORS ARE CLOSED
ATTACK STAIRS CLEARED 5 FLOORS ABOVE
COORDINATE CURTAIN OR BLANKET
-persons found in hallway, remove to EVACUATION STAIR (notify IC)
-persons opening apt. doors…remain if tenable
-person in stairway..remove below fire sector
**ANY STAIRWAY NOT ATTACK IS EVACUATION STAIRWAY **
3RD TRUCK
-CONFIRM EVAC stair doors closed on fire floor , POSITION MEMBERS ON STAIRWELL SIDE OF DOORS until FIRE SECTOR SUP OR IC DEEM THERE IS NO HAZARD
-May be assigned roof ops if not covered
may be assigned floor below for LSR
ROOF FF –brings KO CURTAIN (AS DOES 1ST)
vent support
6th truck
-report to IC with TWO PPV FANS
1ST CONSIDERATION- ATTACK STAIR TO ATTACK FIRE
2ND-EVAC STAIRWELL FOR SMOKE / CO CONTROL
3RD-VENTING PUBLIC HALL
SQUAD DELIVERS WINDOW BLANKET TO FLOOR BELOW FIRE
FIRE SECTOR SUPERVISOR will assign unit to deploy
1ST CHIEF MAY UTILIZE COMMUNICATION SYSTEM FOR EVACUATION OF FIRE FLOORS AND FLOORS ABOVE
2008 code
ONE WAY COMMUNICATION TO ALL STAIRWAYS AND DWELLINGS FOR ALL NEW R2 BUILDINGS GREATER THAN 125 FEET IN HEIGHT
Command POST may be better outside building
IF COMMAND POST OTHER THAN LOBBY, NOTIFY DISPATCHER
-better view
-wind conditions
-exterior stream
-away from Positive Pressure fans
ALL CHIEFS AT 10-77 POST RADIO AND AIDE FULL PPE
1ST BC
give POST RADIO TO 2ND ENGINE OFFICER
-Announce attack stair on HT AND NOTIFY DISPATCHER
-initially 1st and 2nd due truck can close evac doors…3rd truck confirm / maintain
3rd or 4th ENGINE CHAUFFEURS ASSIST IN TRACKING CALLS FROM OCCUPANTS
2ND BC
FIRE SECTOR SUPERVISOR
POST RADIO LEFT WITH INCIDENT COMMANDER
-MOBILITY IN SUPERVISING, BUT DON’T GET INVOLVED IN DUTIES
MAKE SURE FIRST HOSELINE IS IN OPERATION , BEFORE 2ND LINE IS STARTED
**WHEN NECESSARY MAKE SURE HRN IS IN POSITION AND READY TO OPERATE **
WHEN NECESSARY ENSURE ENTRY IS MADE INTO APT FLOOR BELOW FOR WIND CONTROL DEVICE OR HRN
SAE GROUP SUPERVISOR
-searches on floors/stairs/hallways ABOVE FIRE SECTOR
-Located floor above fire sector..NON IDLH IF POSSIBLE
-mobility but not physically involved
-POST RADIO ON COMMAND CHANNEL
MORE THAN ONE SECTOR ESTABLISHED..
COMMAND CHANNEL MUST BE ESTABLISHED
Car fire underneath HRFPMD
SEARCH LINE
TIC
NOISE FROM SPRINKLER
LIMITED PERSONNEL
FANS TO CONTROL SMOKE