High Rise Reference Flashcards
Define a high rise structure…
A residential high rise by CFD definition is 6 stories or more.
A typical fire service definition for high-rise structures is a building that is beyond the exterior reach of the aerial apparatus available.
What is a high rise building construction type?
Type 1 - Fire Resistive. They have non combustible materials and have fire protection by encasement.
List required high rise equipment…
TICS, Drager X-am 2500, Irons, High rise appliance bag, High rise hose packs (44mm and 65mm), Lock box and access keys.
What are three main areas of size up?
Size up should occur at three main areas
- Exterior on arrival
- Lobby area
- Interior staging level to the fire floor
How many floors do interior crews stage below the fire floor?
2 Floors below the fire floor
What are the three priorities of the Incident Action Plan?
- Life Safety
- Incident Stabilization
- Property Conservation
(LIP)
When should stairs be used in a high rise?
When there is an alarm involving 5 floors and below.
When can elevators be used at the discretion of command?
Alarms at 6 floors and above.
What is the minimum number of personnel in an elevator at a fire incident?
3…
Officer (Red Hat)
Elevator Control Person
Firefighter
(Probationary firefighter cannot be the elevator control person)
When should the elevator be stopped to reassess conditions?
Halfway to the desired location to check for smoke and then every five floors to check again. If any smoke is found, the elevator is not to continue any further. Advise command and reassess. Discretion can be used by command if it is felt that checking the elevator shaft every five floors is not necessary.
What are the two designations for stairwells used by the CFD?
Fire attack and evacuation
If Phase 1 cannot be established, what is CFD protocol?
Crews are not to use the elevator and to notify command
What does the forward slash with an engine unit number signify when written at the top of the door in high rise operation?
The forward slash indicated that the primary search has been completed by that company.
What does the back slash and completed X with an engine unit number signify when written at the top of the door in high rise operation?
This signifies that the secondary search has been completed on that floor, by that company.
What are the three types of Interior Standpipe Connections?
Class 1 - (Fire Department use only - 65mm connections)
Class 2 - (Occupant use only - 38mm connections)
Class 3 - Fire Department use and/or occupant use - 65mm and 38mm or 65 to 38mm reducers)