Ch12 Fire Hose Flashcards
CFD categorizes hose into two categories…
Supply and attack
What is a pony hose?
Any hose that is cut shorter than its regular length.
What is the direction of egress with couplings?
Smooth, bump, bump, to the pump
What is the name of the non-threaded coupling on supply lines?
Stortz
What are the CFD 5 methods for coupling/uncoupling hose…
One FF over the hip One FF foot tilt Two FF method One FF knee press Two FF stiff arm method
What is the hose complement on CFD engines?
- 4 lengths of 19mm = 90m (2-30m, 2-15m)
Forestry hose (blue) - 2 lengths of 44mm = 30m
Trash line or bumper line located in front bumper - 8 lengths of 44mm = 120m (4 yellow, 4 orange)
2 transverse beds of 60m in each bed
1 transverse is yellow (first transverse bed)
1 transverse is orange (middle transverse bed) - 1 length of 44mm (30m) has smooth bore
Hose bundle (high rise) - 1 length of 65mm (15m)
Hose bundle (high rise) - 4 lengths of 65mm (60m)
Pre-connected in a transverse - 18 lenghts of 65mm (270m)
Attack bed (devils load) - 10 lenghts of 126mm (300m)
Supply bed
What are the three CFD methods of rolling hose?
Service Roll
Damaged Roll
Single Donut Roll
Explain how a service roll is done…
Start with the male coupling and roll towards the female. (Female is on the outside indicating that it is ready for use).
Explain how a damaged roll is preformed…
Start with the female end and roll towards the male end. The male end out signifies damaged and should also be tagged out of service.
Explain how the single donut is preformed…
This is done on 125mm pony lines. The two fitting are placed a few meters from each other with the hose folded on itself then rolled from the fold to the couplings with the couplings on the outside.
When is hose testing and inspection done? CFD manual…
Annually (black marker is used to mark the year)
After repairs
After hard use
On any suspicion of damage
On CFD engines, what is the area called where the 2 sets of 4 44mm hoses are?
Transverse bed
What are hose appliances?
A device that is used to control the flow of water or create a pathway for water through hose layouts
What is a “wye” appliance?
A “wye” consists of two male connections and one female connection.
What is a “siamese” appliance?
A “siamese” consists of two female connections and one male connection.
As water is vaporized into steam, it expands approximately ____ its original volume.
1700x
What are the three main categories of nozzles?
Hand lines
Master streams (Fixed, portable, combination, and elevated)
Specialty nozzles
Smooth bore nozzles produce what type of stream?
Solid stream
In regards to a co-axial nozzle, the “bumper” produces what two type of streams?
Fog and straight stream