What do most gas meters supply PSI to customers ?
1/4 psi
What is natural gas explosive range?
5% to 15%
Gas shut off are a ______ turn _________.
1/4 turn. Clockwise
What are the priority order when shutting down gas valves ?
- At the appliance. 2. Meter than meter valve than master meter.
- Head of service valve. 4. Exterior gas riser valve
- Curb valve. 6. Street valve
When opening a curb valve in the street and you see a white valve what does this indicate?
Plastic valve that is easily broken
When closing a curb valve how many turns are the most u should do?
15 turns
Can FD shut down a street valve at a gas emergency?
Yes in extreme circumstances and only under the direction of FD IC after consultation with utility rep supervisor.
Can plastic pipe be used inside a structure for gas line?
No
Should FD members attempt to fold or go near plastic gas pipe ?
No
At a gas leak are thermal imaging cameras instringentlly safe?
No
If a gas supply is burning and not shut off what is the best thing to do?
Allow gas to burn off and wet down combustible material around it
At a gas emergency how could you vent it?
Use a fog nozzle out a window
Could we use FD fans to vent a gas emergency?
No not instrincally safe
What is FD indoor action level at a gas leak ?
10%
At a outdoor gas emergency what is FD action level?
20%
When your going to vent at a gas emergency where would you start?
At top and work your way down and out of bldg
If a bldg has positive gas readings how many exposures on both sides should be checked?
3 exposures on both sides
You respond to a order of gas in the street and here a loud roaring sound what is this an indication of?
Outdoor gas leak also high pressure leak
At a gas leak can sewer covers be removed?
Yes if approved by a chief on scene
Can electrical manhole covers be removed by FD members?
Yes but must have the approval of the chief on scene and must be requested by a gas rep on scene . Prior to the removal of the cover a gas rep must check cover for stray voltage.
Can we pull open square or rectangular manhole covers?
No
Can we pull electrical manhole covers if there is a manhole fire in the area or smoke or arcing is observed in a electric manhole or transformer vault?
No do not open
The Altair gas meter will sound an alarm at________.
10% LEL our indoor action level