Gas Emergencies Flashcards

0
Q

What do most gas meters supply PSI to customers ?

A

1/4 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

What is natural gas explosive range?

A

5% to 15%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Gas shut off are a ______ turn _________.

A

1/4 turn. Clockwise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the priority order when shutting down gas valves ?

A
  1. At the appliance. 2. Meter than meter valve than master meter.
  2. Head of service valve. 4. Exterior gas riser valve
  3. Curb valve. 6. Street valve
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When opening a curb valve in the street and you see a white valve what does this indicate?

A

Plastic valve that is easily broken

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When closing a curb valve how many turns are the most u should do?

A

15 turns

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Can FD shut down a street valve at a gas emergency?

A

Yes in extreme circumstances and only under the direction of FD IC after consultation with utility rep supervisor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Can plastic pipe be used inside a structure for gas line?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Should FD members attempt to fold or go near plastic gas pipe ?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

At a gas leak are thermal imaging cameras instringentlly safe?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

If a gas supply is burning and not shut off what is the best thing to do?

A

Allow gas to burn off and wet down combustible material around it

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

At a gas emergency how could you vent it?

A

Use a fog nozzle out a window

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Could we use FD fans to vent a gas emergency?

A

No not instrincally safe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is FD indoor action level at a gas leak ?

A

10%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

At a outdoor gas emergency what is FD action level?

A

20%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When your going to vent at a gas emergency where would you start?

A

At top and work your way down and out of bldg

16
Q

If a bldg has positive gas readings how many exposures on both sides should be checked?

A

3 exposures on both sides

17
Q

You respond to a order of gas in the street and here a loud roaring sound what is this an indication of?

A

Outdoor gas leak also high pressure leak

18
Q

At a gas leak can sewer covers be removed?

A

Yes if approved by a chief on scene

19
Q

Can electrical manhole covers be removed by FD members?

A

Yes but must have the approval of the chief on scene and must be requested by a gas rep on scene . Prior to the removal of the cover a gas rep must check cover for stray voltage.

20
Q

Can we pull open square or rectangular manhole covers?

A

No

21
Q

Can we pull electrical manhole covers if there is a manhole fire in the area or smoke or arcing is observed in a electric manhole or transformer vault?

A

No do not open

22
Q

The Altair gas meter will sound an alarm at________.

A

10% LEL our indoor action level