Fuel Flashcards

1
Q

Main tank composure

A

Crash worthy suction type self sealing, lower 1/3 self sealing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Prime/Boost pump function

A

Primes all fuel lines and boost pump for apu

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

All lines have

A

Self sealing breakaway valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Fuel path

A

Drawn by dngine-driven fuel boost pump through fuel filter to HMU high pressure pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Fuel Filter

A

Has PDI - pressure differential indicator

Doesn’t filter water, which may cause fluctuations/ surges

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Placing fuel pump to fuel prime

A

opens both engine prime shutoff valves allows individual priming of the engines with the PCL in lockout

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Main fuel tank (Location, usable fuel, interconnect)

A

Behind the cabin in the transition section.
590 usable gallons (4012 lbs JP-5)
Interconnect approx. 270-600 pounds per side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Left Cell components

A
Spots for single-point refuel/defuel, gravity refuel, HIFR
2 High level shutoff floats
Check valve
Sump Drain
Vent
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Right Cell components

A
2 check valves
Sump Drain
Vent
APU Fuel line
Fuel Dump system
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

External Tank Size

A

120 or 113 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

External Tank Components

A

Crashworthy, ballistically hardened
self sealing breakaways
Can be gravity fueled, pressure fueled, HIFR, defueled

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

External fuel level measurements

A

Single Guage probe
Low level thermistor exposed when tank empty
Overflow thermistor in vent line (EXT FUEL OVERFLOW)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Aux tank guage and low level switch signal absent

A

FMCP automatically bypasses that station and goes to the next

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Do not initiate unmonitored manual transfer until main is below?

A

3200 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Emergency jettison via ALL STORE JETT is inhibited when less than?

A

40 gallons, 272 lbs, in 50 lb increments, SEL JETT must be used

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When will fuel transfer in AUTO logic

A

Main tank less than 2640

17
Q

Fuel shown in what increments

A

10 lb

18
Q

How is fuel quantity measured

A

capacitance type probe in each cell that uses the fuel as a dielectric

19
Q

1/#2 FUEL LOW caution and digital readouts yellow

A

Fuel in one cell reaches 300 lbs

20
Q

Total readout display turns yellow

A

Total fuel reaches 600 lbs

21
Q

Minimum fuel dump rate

A

800 lbs per minute

22
Q

Refueling with electrical power on

A

all external tank shutoff valves are closed and the main tank is filled first, right external then left external

23
Q

Precheck Switches

A

If moved from center position fuel flow during refueling is stopped

24
Q

If right cell fills faster

A

Monitor fuel quantity, stop transferring fuel before right cell is full (1700 lbs)