Essential Cooling Water (EW) Flashcards
What are the loads EW can carry on a loss of NC?
Priority Heat loads:
-RCP coolers (seal cooler, HP cooler, thrust bearing cooler, motor coolers, motor lube oil coolers)
-CEDM coolers
-Norm Chiller
-Nuclear Sample coolers
Non-Priority Heat loads:
-SFP HXs
What is the design basis maximum temperature that EW will maintain ESF system water to during a LOCA?
135*F
What will autostart EW pumps?
SLAC-CC
SIAS
LOP
AFAS
CSAS
CREFAS
CRVIAS
If EW is isolated from the EC system, which of the two systems is inoperable?
EC only
If EW is isolated from the SDC, which of the two systems is inoperable?
Both
EW can’t maintain its acceptable limits
Between what levels does the auto makeup maintain EW Surge Tank level?
22” and 26”
What are the makeup supply options for EW surge Tank?
Norm - DW
Class ALT - CT
ALT (never use) - Cooling water holdup tank (CM)
Emergency - Fire Protection
What level in the EW Surge Tank will auto close the ‘A’ EW to NC cross-tie valves (EWA-UV-65 and EWA-UV-145)?
Lo-Level 17”
What is the low-level in the EW Surge Tank will isolate makeup? Why?
14”
prevent feeding a leak
What is the purpose of the RHPCV?
prevent stacking
installed at the EW outlet of EC condenser section
closes on low pressure, opens for high pressure
What auto closes the ‘A’ MOV, EW -> NC cross-tie valves?
What can be overridden?
SIAS, Lo Tank level (14”)
SIAS ONLY
What is required to make EW operable again after EW is cross-tied to the SFP-HX?
flow balance on EW