Emergency Panel Flashcards
EMERGENCY PANEL
Q: What buses are powered by the emergency generator?
Ref: (FOM VOL. III-DSC-24-10-30-30)
- AC ESS and AC ESS SHED
- DC ESS and DC ESS SHED
EMERGENCY PANEL
Q: What is the function of the RAT & EMER GEN pushbutton?
Ref: (FOM VOL. III-DSC-24-20)
To provide a backup emergency electric and hydraulic power source.
EMERGENCY PANEL
Q: When will the RAT automatically extend?
Ref: (FOM VOL. III-DSC-24-20)
AUTO – RAT will automatically extend if AC BUS 1 & 2 are not powered and airspeed > 100 knots.
EMERGENCY PANEL
Q: How long does it take the RAT to extend and provide power?
Ref: (FOM VOL. III-DSC-24-10-30-30)
8 seconds (3 seconds for RAT extension, 5 seconds to pressurize the Blue hydraulic system and power the EMER GEN)
EMERGENCY PANEL
Q: What does the red FAULT light on the RAT & EMER GEN pushbutton indicate?
Ref: (FOM VOL. III-DSC-24-20)
Loss of power to AC Bus 1 + AC Bus 2 and the emergency generator is not supplying power.
EMERGENCY PANEL
Q: What powers the emergency generator?
Ref: (FOM VOL. III-DSC-24-10-20)
Blue hydraulic power from the RAT.
EMERGENCY PANEL
Q: Is there another way to deploy the RAT?
Ref: (FOM VOL. III-DSC-29-20)
Yes, RAT MAN ON from the HYD panel.
EMERGENCY PANEL
Q: What is different about deploying the RAT via the HYD Panel?
Ref: (FOM VOL. III-DSC-29-20)
Blue HYD pressure only – No Emergency Generator
EMERGENCY PANEL
Q: What happens when you push the GEN 1 LINE pushbutton?
Ref: (FOM VOL. III-DSC-24-20)
- GEN 1 Line Contactor opens and the white OFF light illuminates
- AC BUS 1 is powered by GEN 2 through the BUS TIE CONTACTOR
- GEN 1 continues to power 1 fuel pump in each wing tank.
EMERGENCY PANEL
Q: When is the GEN1 Line pushbutton used?
Ref: (FOM VOL. III-DSC-24-20)
During smoke procedures.
EMERGENCY PANEL
Q: What does the amber SMOKE light in the GEN 1 LINE pushbutton indicate?
Ref: (FOM VOL. III-DSC-26-30-20)
Smoke detected in the avionics ventilation ducting.
EMERGENCY PANEL
Q: Will there be any OTHER indications when the SMOKE light illuminates on the GEN1 Line pushbutton?
Ref: (FOM VOL. III-DSC-26-30-20)
ECAM warning and amber FAULT lights in the EXTRACT and BLOWER pushbuttons on the VENTILATION panel.