Electrical Systems Flashcards

1
Q

Where is the ELEC power panel located?

A

Overhead Switch Panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How are the main AC generators cooled and lubricated?

A

AFT XSMN Main Oil Lubrication System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The GCUs protect the AC system from what four conditions?

A

Over Voltage, Under Voltage, Under Frequency, Feeder Fault

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where are the No 1 and No 2 AUX PDPs located?

A

Left and Right side Cabin (Mid-Point)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How is the APU generator cooled?

A

Air Cooled

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

An indicator on the center instrument panel indicates when the battery voltage drops below _____ Vdc

A

20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the purpose of the AC bus-tie gang bars on each PDP?

A

Isolate respective system to prevent “bus-tie” from occurring to the other side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

With the BATT switch in the OFF position, the battery supplies DC electrical power only to the _____ bus.

A

Battery Bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The battery bus can be energized by what two sources of DC electrical power?

A

1 and #2 Transformer Rectifier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the order of priority for the DC electrical system from highest to lowest?

A

Transformer Rectifier, External DC Power, Battery

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

True or False? The BATT switch must be in the ON postion in order to recharge or maintain the charge of the battery.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What three DC buses are powered by the battery with the BATT switch in the ON position?

A

Batt Bus, Essential 1 and 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If the APU is running or external AC power is connected, DC power is supplied by the helicopter _____.

A

Transformer Rectifier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the order of priority of power for the AC electrical system from highest to lowest?

A

Main AC Generator, APU Generator, External AC Power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What “system” allows either main generator to provide electrical power to both buses should a single generator fail or be taken off-line?

A

Bus-Tie System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If all three generator switches are placed to the ON position (#1 Main, #2 Main, and APU), which one(s) will provide electrical power to the #1 and #2 AC buses?

A

Each main AC gen will provide power to its respective bus. APU gen power will not be connected to the bus.

17
Q

The primary active caution messages to look for in determining whether or not a bus-tie exists are the respective RECT FAIL (OFF), ENG FUEL PRESS LO, and____

A

AFCS FAIL

18
Q

Should both generators fail, both rectifiers will be ______.

A

Disabled

19
Q

What will be the indications if a bus-tie DOES NOT exist when a RECT1 or RECT2 OFF becomes active?

A

RECT 1 or 2, AFCS FAIL, ENG FUEL PRESSURE

20
Q

What indications will you have that a bus-tie DOES exist during a single generator failure?

A

None besides appropriate GEN caution

21
Q

What is the procedure (first underlined step) for both RECT1 OFF and RECT2 OFF cautions active?

A

LAND AS SOON AS POSSIBLE

22
Q

Each AC generator produces how much power?

A

40 kva and 32,000 watts

23
Q

How do the AC generators produce a current?
How many phases?

A

By creating a change in magnetic field (spinning magnetic)

Three phase AC power

24
Q

How much KVA is produced by APU generator?

A

20 KVA

25
Q

At max load, what % of load can each EAPS fan consume from the AC generators

A

16.5% each