E190 - Oxygen Flashcards
What happens if you press the mask TEST/RESET switch after usage, with the mask doors closed ?
Oxygen flow is shut off, mask microphone is shut off and speakers are cancelled.
When is oxygen supplied through the purge valve in the mask ?
In EMERG mode.
Oxygen masks deploy at a cabin altitude of:
14,000 - (14,750 ft.)
A cyan crew oxygen indication means:
Enough oxygen is still available for 2 crewmembers.
An amber crew oxygen indication means:
No dispatch.
What happens with the green oxygen pressure relief disc in case of overpressure ?
It blows out.
Crew oxygen cilinders size is … ft3, pressurized up to ….. psi. It is installed in the …. cargo compartment. Sufficient oxygen is available for an emergency descent of …. min, followed by … min of cruise at FL100.
50 ft31850 psiforward22 min98 min
Crew oxygen flow starts when…. , until …. .
The mask doors are openedThe mask doors are closed.
Is the headset mic automatically deactivated when the mask door is opened ?
Yes, and the mask mic is activated, together with the speakers.
PBE should supply oxygen for … min and provides positive oxygen pressure up to …. ft.
15 min25,000 ft.
Are oxygen masks available in the galleys, at the flight attendant stations and in the lavatories ?
Yes.
Each PSU should supply for up to … min of oxygen. Depending on the cabin altitude, the masks can supply 100% oxygen, otherwise it is always diluted.
12 min.
Portable oxygen bottles store …ft3of oxygen. They are pressurized to …. psi. A safety disk ruptures at a pressure of around ….. psi.
11 ft31800 psi2700 psi