What happens if you press the fire detection system TEST button for > 10 sec ?
The APU shuts down.
Engine/APU fire detection is powered by:Engine extinguishing is powered by:APU extinguishing is powered by:
DC ESS BUSS-ES
HBB-ES
DC ESS BUS 2
The engine and APU fire detection systems are continuously monitored in a … loop configuration.
Dual.
True or false ? If an engine fire extinguishing bottle is discharged, fire handle illumination may disappear.
True. The fire condition still exists if the CAS msg is still shown.
The indications for an engine fire are:
- WARNING light + aural alert- Fire handle illuminates- FIRE indication on ITT- EICAS warning ENG 1(2) FIRE
The indications for an APU fire are:
- WARNING light + aural alert- APU EMER STOP red bar- EICAS warning APU FIRE
! APU fire button is NOT illuminated
What happens if you press the APU EMER STOP button ? What happens if you press the APU FIRE EXT button?
The APU fuel SOV is closedAPU is shutdown
Same actions as APU EMER STOP +
Discharges the fire bottle
What happens if you don’t press the APU EMER STOP within 1min after an APU fire ?
The APU fire extinguisher pushbutton illuminates.
What happens if you have an APU fire on the ground and you don’t take any action ?
The APU will automatically shut down after 10 sec.
How many APU fire bottles are available ?
One.
The fwd cargo compartment has … smoke detectors, and the aft cargo compartment has … smoke detectors. The fwd and aft cargo smoke detection systems work:
fourthreeIndependent.
In case of a fwd cargo smoke detection, these ventilation systems are automatically turned off:
- The fan is turned off (brings in air from the recirculation bay)
- Ventilation outflow valve is closed
(at the end of the cargo bay)
Both cargo fire bottles are installed in:The agent remains in the cargo compartment for:
The center e-bay60 min.
Use of the cargo fire switch. The bottles are discharged when(annunciated smoke):
First bottle: after the first pushSecond bottle: 1min OR 2nd push
Use of the cargo fire switch. The cargo bottles discharge(non-annunciated smoke):
First bottle: after the second pushSecond bottle: 1min / 3th push (gnd)