What is the CVCS Makeup water subsystem?
Proides pure RX makeup water and borated refueling water to compensate for leakage.
Where can the RX Makeup Water Tansk send nonborated water to?
Gas stripper, liquid radwaste evap, boric acid concentrator, solid radwaste for resin xfrs, charging pumps for seal lube, CVCS chemical add tank, RDT, EDT, VCT, charging pumps suct, RWT, and CVCS HUT.
Where does the high suction line on the RWT send borated water to?
Through BAMP to SFP to the SFP cleanup subsystem, Through Boric acid filter to blending tee to CVCS charging/letdown system to VCT or charging pump suction.
How is the RWT connected to safety injection?
Two 20” line provide water from the RWT to the SI pumps (HPSI, LPSI, and CS)
Where do the gravity feed flow paths lead?
Charging Pump Suction
What is the blending tee?
Combines nonborated water from the RMWT and borated water from RWT to charging pumps. The changes take about 20 mins to see in the VCT.
What is the boric acid batch tank?
Take flow from the RMW pump or BAMP to boric acid batch tank eductor the final solution is directed to the RWT.
What can supply emergency boration via gravity flow?
Spent Fuel Pool
What is the purpose of the Reactor Makeup Water Tank?
Alternate source for safety related Aux FW Pumps, provides dilute Rx Mkup water during norm op, provides hi quality water to promote recycle of dilution water.
What is the design of the Reactor Makeup Water Tank?
Stainless steel 480,000 gal 2 set of redundant 5kW heaters keeps water >40*. Vented to atm and overflow to CVCS HUT sump
What is the normal makeup water supply to the RMWT
Demineralized Water and alternately Recycle Monitor Tank in the liquid radwast system.
What is the purpose of the Reactor Makeup Water Pumps?
Provide makeup water flow from the RMWT throughout the makeup water subsystem.
What is the design of the Reactor Makeup Water Pumps?
CPs rated at 165gpm, power from NH, 1 normally running 1 in standby. Only one pump can run at a time. They trip on lo-lo level and lo discharge pressure.
What is the purpose of the Reactor Makeup Water Recirculation Valve?
Opens to allow recirc of Rx Makeup Water back to RMWT at low dilution flows <20gpm. Closes to provide full dilution flow at hi demands when providing makeup water to the VCT.
What is the design of the Reacttor Makeup water recirculation valve?
Air operated diaphragm valve normally op by CR. Reverse operated….clockwise will open counterclockwise will close it.
What is the design of the Reactor Makeup water recirculation valve?
Air operated diaphragm valve normally op by CR. Reverse operated….clockwise will open counterclockwise will close it.
What is the purpose of the Reactor Makeup Water Flow Control Valve?
Controls reactor makeup water flow through the blending tee into the 1.RCS via the VCT or Charging pump suct. 2.Boric Acid batch tank eductor to either the RWT or CVCS hut.
What is the design of the Reactor Makeup water flow control valve?
A coriolis type sensor measures flow rate RO sets flow rate valve fails closed on loss of air or power to solenoid control valve.
What is the purpose of the Refuling Water Tank?
Supports the ECCS and CS subsystems by providing a source of borated water for ESF pump op, provide borate water for norm op recycle, and provide borated water MKUP during postulated design events.
What is the design of the Refueling Water Tank?
Concrete Tank lined with Stainless steel to meet seismic cat 1. Concrete provides sheilding, stores up to 750,000 gal of water borated to 4000-4400ppm, 2 heaters keep between 60-120F, vented to norm exhaust, overflow 2 CVCS HUT sump.
What is the makeup source to the RWT?
Normal CVCS HUT via CVCS HUT pump. (Chemistry adjusts boron)
When is Boric Acid Batching done?
Shortly before outage to maximize RWT borated water volume for the outage.
How can we transer water from the Safety Injection Tanks to the RWT?
Via LPSI or CS pumps
How do we detect level in the RWT?
4 Class powered level detectors provide a RAS xfrs suction for the SI pumps to the Containment sump and stops the LPSI pump, 1 non-class stops BAMPs on a lo-lo level in the RWT 1 non-class provide level idication and alarms in CR