CGTO PG-85-00-110A 1/1/24 Flashcards
Maintenance quality is the responsibility of whom
all maintenance personnel
1-1
Who designates a QA
Quality Assurance Inspectors QA inspectors shall be selected and designated in writing by the Engineering Officer.
1-1
What causes FOD
Most FOD can be attributed to three general causes: poor housekeeping, poor maintenance practices, and carelessness.
1-2
What is JOAP and who provides funds for it
Joint Oil Analysis Program
CG-41
1-3
How much fuel should be taken for fuel samples
It is recommended that approximately one pint of fuel from each drain be inspected using a clear, clean, dry glass container.
1-5
How much icing inhibitor is in fuel
The normal level of fuel system icing inhibitor in turbine fuel (FSII) is 0.07-0.15 percent by volume
1-5
How much does icing inhibitor lower the flash point of JP-5
4 degrees Fahrenheit and will inhibit the growth of bacteria.
1-5
What manual is the Corrosion Control Program Process Guide
CGTO PG-85-00-60-A
1-6
Use of artificial dehumidification for at least 8 hours per day
has been shown to reduce avionics dispatch failure rates by ___ and may extend structural longevity
40%
1-6
For Calibration Certification and Labeling
TMDE Certification Label color
Limited Use/Special TMDE Certification Label color
white
yellow
1-8
Who shall ensure that an effective calibration program is implemented for assigned equipment and tooling
ANY COAST GUARD AIRCRAFT
Commanding Officers
1-6
Lathes, milling machines, and similar types of equipment that produce cuttings or flying particles should be set at what
15-degree angles to each other, and secured to floors, bases, or stands.
2-2
What is The most effective means of preventing unsafe operations and injuries from powered machinery
improved machine design, or installation of protective
mechanical guards.
2-2
Safety measures for grinders will be established in the following
manner:
- Metal hood type guards shall enclose two-thirds of the
abrasive wheel. - Tool rests shall be adjusted to provide a minimum of 1/8-inch
from abrasive wheel grinding surface
2-3
Sealed lead-acid batteries and sealed nickel-cadmium batteries do not require a dedicated battery room or area, and can
be charged in the same battery room or area as long as a minimum
of _____ of clearance is maintained between the different batteries.
5 feet
2-4
How do you mix electrolyte with water
Pour the electrolyte into the water slowly
Shop personnel shall wear rubber gloves, protective eye glasses and
clothing when handling electrolyte or servicing batteries
Warning Never pour water into the electrolyte, AS INTENSE HEAT IS GENERATED AND MAY RESULT IN BURNS.
2-5
Oxygen cylinder storage shall be separate
from fuel-gas cylinders or combustible materials (especially oil or grease) by at least a distance of __ ft, or have a noncombustible barrier at least _ ft high and have a fire-resistance rating of at least ___
20 ft
5 ft
1/2 hour
2-8, 2-9
What is the most effective type of fire extinguisher for putting out solvent fires
Carbon Dioxide CO2 fire extinguishers, (inert gases)
2-13
What should be used for purging solvent gases from equipment or piping systems and in welding of solvent containers (hot work).
Nitrogen gas
2-13
Coast Guard policy regarding noise hazards and hearing conservation is contained in the
Safety and Environmental Health Manual, COMDTINST M5100.47
2-14
What type of respirators shall be used when applying aircraft polyurethane paint systems.
Full-face or Hood Full-face or hood, type C, continuous flow supplied air respirators
2-14
Single fibers can easily penetrate the skin, break off, and become lodged beneath the skin. What do you use to remove the fibers
Sharp tweezers and a magnification lens are generally required to remove the fiber.
2-15
What type of fire extinguisher is used for aircraft engine starting
A qualified fire guard, adequately equipped with CO2, Halon, or dry chemical fire extinguisher, shall be stationed near the aircraft during engine starting
2-15
Purchase of Halon fire extinguisher for flight line hangar and
shop use is prohibited. Existing Halon fire extinguishers may continue to be used and serviced as long as it is economically feasible.
Should the purchase of replacement fire extinguishers be necessary, flight line fire extinguishers shall be replaced with what type?
150 pound dry chemical type fire extinguishers.
Hangar and shop fire extinguishers shall be either CO2 or dry chemical as recommended by the local fire marshal.
2-16