How many hand operated fire extinguishers are provided on the aircraft
4
CGTO 1C-130J-1
P. 76
How long do you wait to taxi or tow aircraft after overheated brakes have been cooled
15 minutes
CGTO 1C-130J-1
P. 516
What type of cylinder and regulator is used for the MA-1 portable low pressure bottles
A-6 cylinder
A-21 pressure demanded regulator
CGTO 1C-130J-1
P. 540
What is the volume of the MA-1 bottle
280 cubic in
CGTO 1C-130J-1
P. 540
What is considered full pressure and how long will the supply last
450 psi
30 minutes at 400 psi
CGTO 1C-130J-1
P. 540
How many positions are on the selector knob of the regulator
4
CGTO 1C-130J-1
P. 540
If the MA-1 emergency oxygen bottle is not recharged within 2 hours after its pressure is reduced below ____ psi, thebottle must be purged IAW MPC
25
CGTO 1C-130J-1
P. 545
How soon after a hot purge should you service aircraft
NOTE: Aircraft oxygen system servicing will be required to begin within one hour after completion of hot purge process.
MPC 351010.0 P. 2
How far away from any aircraft performing fueling or engine/apu operations should you conduct aircraft purge
CONDUCT PURGING AT LEAST 75 FEET FROM ANY AIRCRAFT PERFORMING FUELING OR ENGINE/APU OPERATIONS.
MPC 351010.0 P. 3
EQUIPMENT SUPPLYING GASEOUS OXYGEN FOR HOT PURGING MUST HAVE SUFFICIENT QUANTITY TO MAINTAIN A CONSTANT FLOW AT ____ PSI FOR ____ MINUTES. DEPLETION OF GASEOUS OXYGEN PRIOR TO COMPLETION OF HOT PURGING EVOLUTION MAY CAUSE DAMAGE TO HOT PURGING UNIT.
90 psi
100 minutes
MPC 351010.0 p. 4
It is recommended that the LMO5HP LOX storage cylinder not be more that what percent full when purging
75 %
MPC 351010.0 p. 4
How far away from aircraft servicing panel should you position the LMO5HP LOX storage cylinder during hot purge
15 ft
MPC 351010.0 p. 4
Ensure electrical power cart has enough fuel to supply power for at least ___ minutes. Failure to do so will result in having to repeat hot purging procedure.
90 minutes
MPC 351010.0 p. 4
How far away should you position power cart from LMO5HP LOX storage cylinder during hot purge
50 ft
MPC 351010.0 p. 4
Where do you place the hot purge unit during a hot purge
Between between storage cylinder and aircraft oxygen servicing panel.
MPC 351010.0 p. 4
Plug one end of the heavy duty extension cord into a ___ ___Hz receptacle on electrical supply cart.
120V 60 Hz
MPC 351010.0 p. 4
What size safety wire is used for the 50 psi relief valve on the LMO5HP storage cylinder
0.020 in steel
MPC 351010.0 p. 6
What do you service LOX IAW
MPC 121401.0 within 1 hour of hot purge completion
MPC 351010.0 P. 6
How long do you allow for dwell time after servicing
30 minutes
MPC 351010.0 P. 7
Ensure that adequate serviceable fire protection equipment is placed within ___ feet of the LOX servicing operation.
50 feet
MPC 121401.0 p. 2
What do you wear for servicing LOX
Wear loose fitting white cotton coveralls, hardhat with integrated ear protection and face shield, cryogenic protective gloves and apron, and black turnout boots (firefighter) certified to NFPA 1971 and NFPA 1992 standards.
MPC 121401.0 p. 2