Brownstones Flashcards

1
Q

Sprinklers in converted MDs and SROs

A

Converted MD: fire escapes added or sprinklers were installed in the interior halls in lieu of secondary means of egress;
SRO: sprinkler lines further extended into individual rooms.
Presence of sprinklers may indicate absence of fire escape (most brownstones- no fire escape)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

One of the most important operations at brownstone fires?

A

VEIS of top floor. Single open interior stair often becomes involved in fire/smoke. Buildup of heat and smoke on top fl is extremely rapid.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Cockloft size in Brownstone

A

2’ to 3’ in height and the roof is pitched toward the rear of the bldg.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Brownstone fire fully involved, IC may order 3rd HL _ “REF”

A

Rear yard of fire bldg through an exposure
Exposure
Fire bldg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Brownstone fire: Extra Engine Extra Truck

A

2 floors of fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Brownstone fire: 2nd Alarm

A

Heavy fire in cellar and basement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Some Brownstones have 2nd set of stairs in addition to main stairs. Choose correct
A. It will be found along a side wall toward the rear of bldg, enclosed from cellar to parlor floor
B. Found in rear of bldg enclosed from basement to 1st fl
C. Found in rear of bldg open from basement to parlor fl
D. Found along side wall or in rear of bldg open and will go from 1st to 3rd fl or will connect 1st, 2nd, and 3rd flrs

A

C

D is found in Queen Anne’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Brownstone fire 3rd fl or 4 story bldg incorrect
A. LCC positioned rig to completely cover fire bldg, raised AL to roof, and immediately moved ladder to VEIS top fl
B. When VEIS top fl, LCC teamed up w/2nd LCC
C. If fire was on top fl, LCC would have raised and positioned AL to roof of exp for use by OV and Roof FF who would go to roof
D. LCC chose middle window on top fl to VEIS instead of window over main entrance

A

A LCC must wait for Roof size up completion prior to moving AL to VEIS top fl

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Choose correct for Brownstone fire
A. All interior HL will be considered 1 3/4” for speed, mobility, and close qtrs
B. Noz FF shall make an announcement via HT when initial hoseline attack is to commence
C. Fully involved fire w/fire showing in exposures, 1st Eng should stretch one 3 1/2” supply line for TL and HL for entering the bldg
D. Fully involved bldg, consider stretching 2 1/2” HL for faster knockdown, greater reach of stream, increased volume of water, and increased exp protection

A

A

C Rowframe fully involved fires
D PD fires

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Converted brownstones to duplex apartments correct
A: When the high stoop remains in place, access to the upper apt will usually be the entrance under the stoop.
B: Open, unprotected stairs between floors within each apartment.
C: Partial areas of the floors may be cut out to create three-story high ceilings and balconies.
D: In all cases, ventilation of the roof will only provide ventilation for the apartments on the upper floors.

A

B
Brownstones sect 2.2.13
A. Where the high stoop remains in place, access to the lower apt will usually be the entrance under the stoop.
C. Partial areas of the floors may be cut out to create TWO story-high ceilings and balconies.
D. In SOME cases, ventilation of the roof will only provide ventilation for the apartments on the upper floors.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly