AUXILARIES ENG Flashcards
HOW MANY A/C PLANTS DO WE HAVE ON BOARD?
5
WHERE ARE THE A/C PLANTS LOCATED?
1 & #1A IN AUX 1
#2 & #3 IN AUX 2
#4 SHAFT ALLEY
WHAT TYPE OF A/C PLANTS DO WE HAVE ON BOARD?
200 TON CENTRIFUGAL YORK
WHAT IS THE PRIMARY PURPOSE OF THE A/C PLANTS?
COOLING ELECTRONIC EQUIPMENT
HOW MANY CHILL WATER EXPANSION TANKS DO WE HAVE ON BOARD?
3
WHERE ARE THE CHILL WATER EXPANSION TANKS LOCATED?
2 AUX 2
AUX 1
AUX 2
SHAFT ALLEY
HOW MANY REFIGERANT PLANTS DO WE HAVE ON BOARD?
2
WHERE ARE THE REFIGERANT PLANTS LOCATED?
REEFER DECKS
WHAT TYPE OF REFIRGERATION PLANTS DO WE HAVE?
1 ½ TON ROTARY VANE
WHAT ARE THE 5 PARTS OF THE REFRIGERATION CYCLE?
RECEICER, TXV, EVAPORATOR, COMPRESSOR, CONDENSER
WHAT TYPE OF DISTILLING PLANTS DO WE HAVE ON BOARD?
REVERSE OSMOSIS
WHAT DO WE USE TO TREAT THE WATER?
BROMINE
WHAT ARE THE 3 WAYS TO TREAT THE WATER?
INLINE BROMINATOR, RECIRC BROMINATOR, AND THE BATCH METHOD USING HTH
HOW MANY GALLONS PER DAY CAN EACH R.O. MAKE?
12,000 GALLONS PER DAY
HOW MANY POTABLE WATER TANKS DO WE HAVE?
4
WHAT ARE THE POTABLE WATER TANKS LOCATION?
1 & 3 AUX 1, 2 & 4 FORWARD POWER CONVERSION ROOM
WHATS THE TOTAL GALLONS WE CAN FILL ALL 4 POTABLE WATER TANKS TO?
15,628 GALLONS
HOW MANY POTABLE WATER PUMPS DO WE HAVE ON BOARD?
2
WHERE ARE THE POTABLE WATER PUMPS LOCATED?
LOWER LEVEL AUX 1
WHERE ARE THE 5 PLACES YOU CAN STEER THE SHIP?
BRIDGE HELM, AFT STEERING HELM, LCU’S, ELECTRIC PUMP, HAND PUMP
WHAT HAPPENS IF WE HAVE TO END UP USING THE HAND PUMP?
WE SET THE RUDDERS TO 0 DEGREES AND LOCK WITH THE RATCHETS TO SET UP TO BE TOWED
WHAT ARE THE THREE MODES OF STEERING?
COMPUTER ASSISTED AUTO, COMPUTER ASSISTED MANUAL, BACK UP MANUAL
WHAT’S THE DIFFERENCE BETWEEN COMPUTER ASSISTED AND BACK UP?
COMPUTER ASSISTED USES DMS TO SEND THE SIGNAL TO THE HPU’S BACK UP DOESN’T
WHAT ARE THE THREE STOPPERS ON THE RAMS?
COPPER, IRON, BLOCK
WHERE IS THE RO DEMINERALIZER?
AUX 1 UPPER LEVEL
WHAT ARE THE THREE BIGGEST THINGS WE USE DISTILLED WATER FOR?
GTM’S AND GTG’S WATER WASH, CND & SPY COOLING SKID, SONAR SKID
- HOW MANY SEAWATER SERVICE PUMPS DO WE HAVE?
5
- FWD TO AFT, WHERE ARE EACH OF THE SEAWATER SERVICE PUMPS LOCATED?
1 AUX1, #2 MER1, #3 AUX2, #4 MER2, #5 SHAFT ALLEY
- WHAT ARE THE SEAWATER SERVICE PUMPS RATED AT?
1,450 GPM @ 35 PSI
- UNDERWAY, WHO IS OVERALL IN CHARGE OF THE ENGINEERING PLANT?
EOOW
- WHAT DOES MPA STAND FOR AND WHO IS IT ON BOARD?
MAIN PROPULSION ASSISTANT
WARRANT AVENA
- WHAT DOES AUXO STAND FOR AND WHO IS IT ON BOARD?
AUXILLARIES OFFICER
ENS PROMISE
- WHAT DOES EOOW STAND FOR?
ENGINEERING OFFICER OF THE WATCH
- WHAT DOES SCU STAND FOR?
SHAFT CONTROL UNIT
- HOW MANY SCU’S DO WE HAVE AND WHERE ARE THEY LOCATED?
2/ MER1 & MER2
- WHAT DOES PACC STAND FOR?
PROPULSION AND AUXILLARY CONTROL CONSOLE
- UNDERWAY, NAME THE MINIMUM PERSONNEL REQUIRED TO BE ON WATCH?
EOOW, PACC OPERATOR, EPCC OPERATOR, ERO1, ERO2, PSM1, PSM2, ASM, SOUND & SECURITY AND OIL KING
- INPORT, NAME THE MINIMUM PERSONNEL REQUIRED TO BE ON WATCH?
CCS WATCH, SOUND & SECURITY/IE