Automated Blood Cell Analysis Flashcards

1
Q

Examine the histograms/scatterplots obtained from four major instruments for the same patient specimen (Figure 15-14,
A-D).
Compare the results, and respond to questions 1 to 4 based on the results.

  1. Which printout lets the end user know at a glance that the
    results are acceptable and no manual work needs to be performed?
    a. CELL-DYN Sapphire
    b. UniCel DxH 800
    c. ADVIA 2120i
    d. Sysmex XN-series
A

d. Sysmex XN-series

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  1. Which instrument printout has a system flag on the platelet
    count?
    a. CELL-DYN Sapphire
    b. UniCel DxH 800
    c. ADVIA 2120i
    d. XN-series
A

a. CELL-DYN Sapphire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  1. What do you suspect is the cause of the variation in platelet
    counting among the four instruments?
    a. Different instruments have different levels of sensitivity.
    b. All instruments use the same principle for counting
    platelets.
    c. Some instruments are susceptible to false-positive platelet flagging under certain conditions.
    d. Different instruments use different thresholds to capture
    and count platelets
A

d. Different instruments use different thresholds to capture
and count platelets

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  1. Based on the overall flagging for this specimen on each instrument, should a manual differential count be performed
    for this patient?
    a. Yes, because immature granulocytes are present in the
    sample.
    b. Yes, because the WBC scatterplots are abnormal.
    c. No, because each differential count is complete with no
    system or morphology flags.
A

c. No, because each differential count is complete with no
system or morphology flags.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  1. A patient peripheral blood film demonstrates agglutinated
    RBCs, and the CBC shows an elevated MCHC. What other
    parameters will be affected by the agglutination of the
    RBCs?
    a. MCV will be decreased and the RBC count will be
    increased.
    b. MCV will be decreased and the RBC count will be
    decreased.
    c. MCV will be increased and the RBC count will be
    decreased.
    d. MCV will be increased and the RBC count will be
    increased
A

c. MCV will be increased and the RBC count will be
decreased.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  1. . Match the cell-counting methods listed with the appropriate definition:
    ____ Impedance
    _____RF
    ______Optical scatter

a. Uses diffraction, reflection, and
refraction of light waves
b. Uses high-voltage electrical waves
to measure the internal complexity of cells
c. Involves detection and measurement of changes in electrical
current between two electrodes

A

__C__ Impedance
___B__RF
____A__Optical scatter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  1. Low-voltage DC is used to measure:
    a. Cell nuclear volume
    b. Total cell volume
    c. Cellular complexity in the nucleus
    d. Cellular complexity in the cytoplasm
A

b. Total cell volume

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
  1. Orthogonal light scatter is used to measure:
    a. Cell volume
    b. Internal complexity of the cell
    c. Cellular granularity
    d. Nuclear density
A

b. Internal complexity of the cell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  1. On the Beckman Coulter instruments, hematocrit is a calculated value. Which of the following directly measured parameters is used in the calculation of this value?
    a. RDW
    b. Hemoglobin
    c. MCV
    d. MCHC
A

c. MCV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
  1. Match each instrument listed with the technology it uses to determine WBC differential counts.

___ Abbott CELL-DYN
Sapphire

___ Siemens ADVIA
2120i

___ Sysmex XN-1000

___ Beckman Coulter
UniCel DxH 800

a. Volume, conductivity, and
five angles of light scatter
b. MAPSS technology and
three-color fluorescence
c. Peroxidase-staining absorbance and light scatter
d. Detection of forward and
side scattered light and
fluorescence

A

__B_ Abbott CELL-DYN
Sapphire

__C_ Siemens ADVIA
2120i

__D_ Sysmex XN-1000

__A_ Beckman Coulter
UniCel DxH 800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly