AOP-7 Rapid Downpower Flashcards

1
Q

What is the purpose of AOP-7?

A

Used when a rapid power reduction is dictated by abnormal plant conditions. A rapid (emergency) power reduction is performed at greater than the maximum normal rate of 30%/hour.

Power reduction less than or equal to 30% power is performed in accordance with GOP-8, “Power Reduction and Plant Shutdown to Mode 2 or Mode 3 >=525F.”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the AOP-7 entry conditions?

A
  • When directed by another abnormal operating procedure.
  • CRS determines that abnormal plant conditions requires immediate power reduction at a rate greater than 30%/hour and less than or equal to 300%/hour.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the auto and immediate actions of AOP-7?

A

None

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the reactor trip criteria of AOP-7?

A

Either Steam Generator level less than 30%
Either Steam Generator level greater than 95%

Pressurizer level less than 30%
Pressurizer level greater than 62.8%

TAVE less than 525F

Rack C, EK-0605, “TM/LO PRESSURE CHANNEL PRE-TRIP”

Rack B, EK-0608, “HI PRESSURIZER PRESSURE CHANNEL PRE-TRIP”

More than one control rod misaligned (8 inch deviation) after attempted realignment

Plant cannot be stabilized following termination of power reduction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly