AOP-36, Loss of Component Cooling Flashcards

1
Q

What is the purpose of AOP-36, Loss of Component Cooling Water?

A

Does NOT address loss of cooling which is loss of SW. This addresses loss of fluid or flow.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the Entry Conditions for AOP-36?

A
  • T-3, CCW Surge Tank level lowering and not being recovered
  • CCW cooled components indicate degraded cooling
  • EK-1169, “COMPONENT CLG PUMP DISCHARGE LO PRESS” (80 psig)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the automatic actions of AOP-36, Loss of CCW?

A

Standby pump starts at 80 psig.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the trip criteria of AOP-36, Loss of CCW?

A
  • CCW flow to Containment lost for greater than 10 minutes
  • Failure to restore a Component Cooling Water Pump to service
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the immediate actions of AOP-36, Loss of CCW?

A

None

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What inventory is needed in T-3, CCW Surge Tank, for pump operation?

A

Greater than 47%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What and where are the temperature indications checked for components cooled by CCW?

A
  • PCP Seal temperatures
    • LTVR-0901 on Panel EC-11
  • TIC-0203, Low Pressure Letdown Flow Temp Control
      • TIA-0931, TIA-0933, Reactor Shield Cooling Coil Outlet Temps
  • FI-0971, FI-0972, FI-0973, Comp Clg Wtr Outlet Flow Charging PPs
  • TI-0912, TI-0913, Shutdown Heat Exchanger Outlet Temp (if in service)