Air Conditioning Panel Flashcards
ENG 1(2) BLEED valves open if?
Start UP APU WOOF
Start valve (engine) is closed
UP-stream pressure sufficient
APU bleed valve closed.
Wing or pylon leak
Over-temperature
Overpressure
FIRE pb (engine) not pushed.
ENG 1 or 2 BLEED FAULT?
w/ ECAM fault
Start (UP)APU’s WOO(F)
Start valve (engine) not closed APU bleed ON (apu valve not closed) Wing or engine bleed leak Over-temp Over-pressure downstream
FAULT will reset w/ ENG BLEED pb is selected OFF and no more fault.
“RAM AIR” (black wire guarded pb) will open the ram air valve if……?
- less than 1psi cabin differential
- ditching pb is not pushed
APU BLEED pb ON (blue) means the valve is open
and the Amber fault light indicates what?
bleed leak.
What does the Pack FAULT represent?
- Valve position disagree (Pack flow control valve)
- Compressor outlet overheat
- Pack outlet overheat.
What is the auto detent on the X BLEED knob?
XBleed valve open = APU bleed valve open.
Closed if closed.
HOT AIR pb FAULT meaning?
a duct overheat. Valve and trim air valves close automatically.
PACK FLOW selector knob has three positions:
NORM LO HIGH
When is high flow automatic?
APU bleed or single pack operation regardless of switch position.
What does the “low” setting do on the pack flow knob?
Reduce pack output to 80%
When is the pack flow control switch set to low?
If # of Customers is below:
140 (320 and Mint)
168 (321)
A320 has 150/162 config.