AGAPPE Flashcards

1
Q

This reagent is intended for in vitro quantitative determination of glucose in serum, plasma and CSF

A

Intended use: Glucose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

GOD-PAP abbrev

A

Glucose oxidase- Phenol amino phenazone

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

GOD-PAP methology kay linear siya up to _________

A

600 mg/dl

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

_______ is a major carbohydrates present in blood and serves as primary source of energy

A

Glucose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

ingested from starch and sugar

A

Glucose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Quinonimine produce color ________

A

Red

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

MSDS will be provided on request

A

Risk and Safety

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Glucose reagent and standard are ready to use

A

reagent preparation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The sealed reagents _________ are stable up to the expiry date on the label, when stored at ______ from the light

A

Reagent storage and stability - 2-8 degree celcius

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Once opened, the reagent is stable up to _______ at __________, if contamination is avoided.

A

Open Vial Stability - 2-8 degrees celcius

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

On-board calibration stability is _______

A

20 days

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

turbidity or precipitation in any kit component indicates detoriarition and the component must be discarded

A

reagent detoriation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

to avoid contamination use clean laboratory wares.

Avoid direct exposure if reagent to light. do not blow into the reagetnt

A

Precaution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Reagents must be disposed off in accordance with local regulations

A

waste managements

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Serum/plasma free of hemolysis/CSF

A

Sample

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

mode of reaction

17
Q

Slope of reaction

A

increasing

18
Q

wavelength

A

505 (440-550) nm

19
Q

Temperature

A

37 degrees celcius

20
Q

Standard concentration

21
Q

Linearity

22
Q

incubation time

A

10 minutes

23
Q

blank

24
Q

sample volume

25
Reagent volume
1000 uL
26
Cuvette
1 cm light path
27
It is recommended that each laboratory establish its own reference values
reference range
28
It is recommended to use aggape qualicheck norm and path
quality control
29
this reagent is linear upto ________
linearity