What is the purpose of 72ST-9RX03?
Verify TS limits for DNBR, LHR, AZ TILT and ASI aren’t exceeded when COLSS is OOS >20% RTP
How often do we monitor the LIMITS for LHR, AZ TILT, DNBR and ASI when COLSS is OOS (Performance Intervals)?
DNBR and LHR - Every 2 hours w/ additional monitoring required at 15 minute intervals under certain conditions
ASI - Every 2 Hours
AZ TILT - Every 12 Hours
Per 72ST-9RX03, who performs the ST’s and who runs the CECOR program?
Operations performs the ST’s
RX Engineering runs CECOR program
AZ TILT can’t be calculated if ANY ___ Instrument is INOPERABLE
Excore Safety Channel
If power can’t be maintained within a range of plus or minus ___ RTP, Adverse Trend monitoring can’t be performed.
1%
During a slipped or dropped CEA event, CPC values of DNBR and LHR are ___ and aren’t to be used to surveil DNBR and LHR to meet LCO 3.2.1 and 3.2.4 requirements.
Non-Conservative
During DNBR, LPD and ASI Evaluations, failing to begin adverse trending within 15 minutes of loss of COLSS results in what?
Tech Spec Non-Compliance
When monitoring DNBR/LPD values for Adverse Trend, what do PURPLE back lit points indicate?
Data is considered SUSPECT
AZ TILT is determined to be More Accurate and is Preferred if CMC is available by this method:
CECOR Snapshot
CPC calculated values of DNBR and LHR are impacted by changing what value?
CPC AZ TILT Allowance (also impacts 15 minute adverse trend data)