(10) VISUAL INSPECTION AND OTHER NDE METHODS AND SYMBOLS Flashcards
Q10-1
Which of the following nondestructive testing methods are limited to the detection of surface discontinuities?
a. visual
b. penetrant
c. radiographic
d. a and b above
e. b and c above
Q10-1
Which of the following nondestructive testing methods are limited to the detection of surface discontinuities?
D. a and b above
a. visual
b. penetrant
Q10-2
To be most effective, visual inspection should be performed:
a. before welding
b. during welding
c. after welding
d. all of the above
e. none of the above
Q10-2
To be most effective, visual inspection should be performed:
D. all of the above
a. before welding
b. during welding
c. after welding
Q10-3
The time period during which the penetrant remains on the surface of the part allowing it to be drawn into any surface discontinuities is called:
a. waiting time
b. penetrating time
c. soak time
d. dwell time
e. none of the above
Q10-3
The time period during which the penetrant remains on the surface of the part allowing it to be drawn into any surface discontinuities is called:
d. dwell time
Q10-4
Which type of magnetizing current provides the best iron particle mobility?
a. AC
b. DC
c. DCEP
d. b and c above
e. all of the above
Q10-4
Which type of magnetizing current provides the best iron particle mobility?
a. AC
Q10-5
What MT technique could be used for the discovery of longitudinal flaws?
a. head shot (circular magnetism)
b. side shot
c. coil shot (longitudinal magnetization)
d. a and b above
e. b and c above
Q10-5
What MT technique could be used for the discovery of longitudinal flaws?
a. head shot (circular magnetism)
Q10-6
Which of the following magnetizing methods produce a circular magnetic field in the test piece?
a. head shot
b. passing an electrical current through the part
c. prod
d. all of the above
e. none of the above
Q10-6
Which of the following magnetizing methods produce a circular magnetic field in the test piece?
D. all of the above
a. head shot
b. passing an electrical current through the part
c. prod
Q10-7
Which of the following magnetizing methods can produce a longitudinal magnetic field in the test piece?
a. head shot
b. coil shot
c. yoke
d. a and b above
e. b and c above
Q10-7
Which of the following magnetizing methods can produce a longitudinal magnetic field in the test piece?
E. b and c above
b. coil shot
c. yoke
Q10-8
What NDT method is best for evaluating subsurface porosity?
a. PT
b. MT
c. RT
d. VT
e. all of the above
Q10-8
What NDT method is best for evaluating subsurface porosity?
c. RT
Q10-9
Which of the following statements is correct for radiographic testing?
a. A reduction in thickness will produce a lighter image on the film.
b. A low density discontinuity will produce a lighter image on the film.
c. A high density discontinuity will produce a lighter image on the film.
d. a and b above
e. b and c above
Q10-9
Which of the following statements is correct for radiographic testing?
c. A high density discontinuity will produce a lighter image on the film.
Q10-10
Radiographic testing (RT) can be performed using which of the following?
a. X-ray machine
b. Cesium 137
c. Iridium 192
d. Cobalt 60
e. all of the above
Q10-10
Radiographic testing (RT) can be performed using which of the following?
E. all of the above
a. X-ray machine
b. Cesium 137
c. Iridium 192
d. Cobalt 60
Q10-11
MT can be used most effectively to inspect which of the following?
a. austenitic stainless steel welds on carbon steel
b. austenitic stainless steel welds on stainless steel
c. carbon steel welds on carbon steel
d. a and b above
e. b and c above
Q10-11
MT can be used most effectively to inspect which of the following?
c. carbon steel welds on carbon steel
Q10-12
Which of the following discontinuities will not usually be revealed using RT?
a. crack
b. incomplete joint penetration
c. porosity
d. lamination
e. none of the above
Q10-12
Which of the following discontinuities will not usually be revealed using RT?
d. lamination
Q10-13
What device is used during radiography to indicate the resolution sensitivity of a radiograph?
a. IQI
b. dosimeter
c. lead screen
d. all of the above
e. none of the above
Q10-13
What device is used during radiography to indicate the resolution sensitivity of a radiograph?
a. IQI
Q10-14
Which nondestructive test method uses sound energy as a probing medium?
a. MT
b. RT
c. UT
d. PT
e. ET
Q10-14
Which nondestructive test method uses sound energy as a probing medium?
c. UT
Q10-15
The process whereby ultrasonic indications are related to dimensions in a test standard is referred to as:
a. setup
b. calibration
c. standardization
d. synchronization
e. none of the above
Q10-15
The process whereby ultrasonic indications are related to dimensions in a test standard is referred to as:
b. calibration