Week 8 - Trains That Cannot Be Relied Upon To Operate Track Circuits Flashcards
When must you use regulation TS1 Reg 12 (trains that cannot be relied upon to operate track circuits)
- Driver of an OTM tells you that the OTM cannot be relied upon to operate track circuits
or
- You are told that a train cannot be signalled normally because a TCA on the train has become defective
When can you allow a train to follow a train that cannot be relied upon to operate track circuits? (TS1 Reg 12.3)
When the train concerned has passed beyond the overlap of a signal that has been placed and kept at danger
Who must you inform about a train that cannot be relied upon to operate track circuits? (TS1 Reg 12)
- Next signaller who is to signal that train
- Level crossing keepers if they rely on the operation of track circuits to alert them of approaching trains
- Anyone else if necessary
What instructions should you give to the driver of train that cannot be relied upon to operate track circuits? (TS1 Reg 12.3)
If necessary, you must tell the driver of the train concerned to stop specially to report the arrival of the train at a specified signal or location
How would you set the route for a train that cannot be relied upon to operate track circuits? When can you operate the points once the train is passing through the route? (TS1 Reg 12.2)
- Set points using IPS (Individual Points Switches)
- You must not operate points that are locked by track circuits until the train concerned has passed well clear of them