Week 4: Engineered Safety Feature Actuation Signals Flashcards
What are the ESFAS signals?
SIS
CISA
CISB
CRVIS
FWIS
MSLIS
FBIS
AFAS
CSAS
What is the function of a SIS?
To shutdown the reactor, maintain the reactor shutdown, and ensure containment integrity.
What conditions will initiate a SIS?
Low SL pressure, 615 psig
Low PZR pressure, 1849 psig
High CTMT pressure, 3.5 psig
Manual
What is the function of a CISA?
To isolate all lines penetrating the containment not essential to Reactor Protection.
What conditions will initiate a CISA?
SIS
Manual
What is the function of a CPIS?
To isolate the CTMT purge system to prevent the release of radioactive material to the environment.
What conditions will initiate a CPIS?
CSIA
Rad monitors in purge system or CTMT reading high
Manual
What is the function of a CRVIS?
To ensure suitable atmosphere in the control room.
What conditions will initiate a CRVIS?
SIS
CPIS
CR ventilation rad monitors
FBIS
CL gas detection
Manual
What is the function of a FWIS?
To minimize the excessive cooldown that can result from overfilling the SGs.
What conditions will initiate a FWIS?
Hi SG level, 78%
Rx trip with low Tavg (564F)
SIS
Lo-Lo SG Level
What is the function of a MSLIS?
To prevent the excessive cooldown that would result from a SLB.
What conditions will initiate a MSLIS?
Low SL pressure, 615 psig
High SL pressure rate with SIS blocked, 100 psig down in 50s
Hi-2 CTMT pressure, 17 psig
Manual
What is the function of a FBIS?
To prevent the release of radioactive material to the environment.
What conditions will initiate a FBIS?
Radiation monitors in the FB ventilation system
Manual