Water / Waste DSC 38 Flashcards

1
Q

Where is the potable water tank located?

A

In front of the wing box, behind the FWD cargo compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many litres does the potable water tank hold?

A

200 litres

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How is the water system pressurized on the ground?

A

By air from the service panel pressure port, or

the air-supply boost system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How is the water system pressurized in the air?

A

By Bleed Air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

To where is potable water piped?

A

To the galleys and lavatories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where are the manual water system shut-off valves located?

A

Under the wash basins and toilet bowls

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where is the indication of the tank water quantity displayed?

A

On the FAP and the AFT Service Panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Where does waste water from the galleys and lavatories go?

A

Drains overboard through 2 heated drain masts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How is the waste water discharged?

a) on the ground?
b) in flight?

A

a) Gravity

b) Differential pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where does waste from the toilet bowl go?

A

Into a waste tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the capacity of the waste tank?

A

170 litres

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When is differential pressure for waste discharge generated by the Vacuum generator?

A

On the ground, and

In flight below 16000ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The Vacuum System Controller (VSC) transmits info to….

a) ?
b) ?

A

a) FAP to indicate waste tank levels and report defects

b) Centralized Fault Display System (CFDS) to signal the system defects to maintenance.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How is the waste tank serviced?

A

By ground personnel via the Service panel AFT RHS under the fuselage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What can be used in case of an electrical failure of the flush valve?

A

The manual flush control which is located under each toilet bowl.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly