SQ: Radiation Monitoring Flashcards
What are the ESFAS related signals that are generated by SQ?
CREFAS
FBEVAS
CPIAS
What are the non-safety related automatic functions generated by SQ?
Through Filter Mode in AR
GR isolation
AS condensate to LR
What is the power supply to the safety related radiation monitors?
PN
From where can you read radiation monitors?
Locally
RMS workstation
ERFDADS
What does Green signify in SQ?
Normal Reading
What does Yellow signify in SQ?
Alert Reading
What does Orange signify in SQ?
Problem
What does Red signify in SQ?
Alarm Reading
Which radiation monitors are covered under the ODCM?
Waste Gas (RU-12) Plant Vent (RU-143/144) Fuel Building Vent (RU-145/146)
What is RU-1
Containment Atmosphere
What are RU-2 and RU-3?
EW System Radiation Monitors
What are RU-4 and RU-5?
SG Blowdown
What is RU-6?
NC System Monitor
What is RU-7?
AS Condensate Receiver Tank monitor
What is RU-12?
Waste Gas Decay Tank Discharge
What is RU-14?
Radwaste Building Vent
What is RU-15?
Waste Gas Area combined vent
What is RU-17?
Incore Instrument Containment area monitor
- De-energized while at power!
What is RU-18?
Control Room Area monitor
What is RU-19?
New Fuel Area monitor
What are RU-29 and RU-30?
Control Room Vent Intake
What is RU-31?
Spent Fuel Pool Area monitor
What is RU-33?
Refueling Machine Area monitor
What is RU-34?
Refueling Purge Exhaust monitor
What are RU-37 and RU-38?
Power Access Purge Area monitors
What are RU-139 and RU-140?
Rad monitors on MS lines in MSSS
What is RU-141?
Condenser Vacuum/Gland Seal monitors
What is RU-142A-D?
Rad monitors on MS lines inside Turbine Building
What are RU-143 and RU-144?
Plant Vent Low/High Range Monitor
- Also monitors humidity
What are RU-145 and RU-146?
Fuel Building Low/Mid/High Range Monitors
What are RU-148 and RU-149?
High Range Containment Area Monitors
What are RU-150 and RU-151?
Primary Coolant Monitors
What is RU-155D?
Letdown Line Monitor
What ESFAS Signal will isolate RU-1?
CIAS
What is the basis for RU-1?
It will detect a 1 gpm leak in Containment in 1 hour
Which RU monitor will be the first to alarm during SGTR
RU-7
When RU-7 reaches its setpoint, what happens?
AS Condensate is directed to the LRS
What signal is generated when RU-29 or RU-30 reaches its setpoint?
CREFAS
What signal is generated when RU-31 reaches its setpoint?
FBEVAS
What happens when RU-37 or RU-38 reaches its hi-hi setpoint?
CPIAS
What is the basis for RU-141?
1 gpm SGTR with 1% failed fuel
What is the basis for RU-142A-D?
30 gallon per day upper tube bundle leak on the hot side
What will RU-143/RU-145 and RU-144/RU-146 do when they reach their max range?
They’ll start their associated high range monitors and then shut down.
What is the basis for the alarm on RU-155D?
Based on 1% failed fuel. Has a “keep alive source” so that rad levels have to reach >10 mrem/hr before they register.